Installation
309967C 7
Models 246910, 253362, and 253384 (FIG. 2)
1. Remove the cover from the pail, and scoop the
lubricant from the center to the sides of the pail to
make its surface concave.
2. Center the follow plate (5) in the pail opening. Press
the plate firmly downward and rotate it over the
lubricant surface to eliminate air pockets and pre-
vent channeling.
3. Insert the pump through the cover (4a) and slide the
cover up far enough to let the pump pass easily
through the follow plate grommet. The pump stop
plate(4b) will secure the pump in place.
4. Place the cover (4a) on the pail, and tighten the
thumbscrews (4f).
5. Assemble the gun (2b) and hose (2a), and connect
the hose to the pump fluid outlet.
6. Connect the nipple (2d) to the pump air inlet or air
regulator (9b) inlet, whichever is applicable. Con-
nect the quick–disconnect coupler (2c) to the air
supply hose.
F
IG. 2
9b
2c, 2d
4f
5
4a
2b
2a
Model 253384 shown
01517
4b