Installation
Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
Pump: use a ground wire and clamp. Loosen the
grounding lug locknut and washer. Insert one end of a
1.5 mm
2
(12 ga) minimum ground wire into the slot in
lug and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. Order Part
237569 Ground Wire and Clamp.
Air and fluid hoses: use only electrically conductive
hoses.
Air compressor: follow manufacturer's recommenda-
tions.
Spray gun/dispense valve: ground through connection
to a properly grounded fluid hose and pump.
Fluid supply container: follow your local code.
Object being sprayed: follow your local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the spray
gun/dispense valve firmly to the side of a grounded
metal pail, then trigger the gun/valve.
FIG. 4
ti8250a