Run Mode
332317C 25
Run Mode
Time Control
After setup is complete, the G1 automatically begins to
run the OFF Time sequence.
• The G1 runs the
programmed OFF
sequence.
(Notice the dot
below OFF flashes
on the display
while the OFF
Time counts down.
This count down is in hours.)
• When the OFF
Time count
reaches zero, the
G1 Automatic
Lubrication Pump
turns the pump on
and it runs for the
programmed ON
Time cycle.
(Notice the dot below ON flashes on the display.)
• When the ON Time count reaches zero, the pump
shuts off again and the system again runs OFF
Time cycle and the OFF Time LED flashes again.
This sequence repeats itself until the device is
reprogrammed or a Low Level Fault occurs.
• If power to the pump is lost during a lubrication
cycle, when power is restored the pump will resume
the cycle with the same amount of time remaining in
the cycle as when the power was lost.
Low Level
Pumps equipped with low level detection will stop when
the fluid level is sufficiently low to trigger the low level
fault.
• The LED next to the LOW LEVEL
ICON on the display flashes.
Add lubricant to the pump. See Loading Grease
instructions, page 19 or Filling Oil Unit, page 20.
• After lubricant is added, press the
RESET button to clear the fault.
NOTE: For higher viscosity fluids it may be
necessary to clear the low level fault prior to
filling the pump. You can then press the
Manual Start button to start the pump during
the fill.
Manual Run Cycle
To run an extra (non-programmed) lubrica-
tion cycle, push the Manual Start button.
NOTE: An Illuminated Remote Run Button
Kit: 571030, 571031 for starting a manual run cycle
remotely if used in conjunction with a 5-wire CPC cable,
is available from Graco. Contact your local Graco distrib-
utor or Graco Customer Service for additional informa-
tion about these kits.