Graco 256713 Heat Pump User Manual


 
23308118
Technical Data (10:1 President)
Fluid Outlet Pressure Chart
0
200
400
600
800
1000
1200
1400
1600
1800
012345
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
PUMP OUTLET PRESSURE
10020 40 60
CPM
80
3.8 7.6 11.4 15.2 19.0
GPM
l/min
A
B
C
7.0, 70
4.2, 42
PSI
5.6, 56
2.8, 28
8.4, 84
11.0, 110
MPa, BAR
9.6, 96
12.5, 125
To find Outlet Pressure (MPa/bar/psi) at a specific
delivery (liter/min or gpm) and operating air pressure
(MPa/bar/psi):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with
selected fluid outlet pressure curve.
Curve slopes from left to right.
Follow left to scale and read outlet pressure.
A 1.25 MPa, 12.5 bar (180 psi) air pressure
B 0.7 MPa, 7 bar (100 psi) air pressure
C 0.49 MPa, 4.9 bar (70 psi) air pressure
D 0.28 MPa, 2.8 bar (40 psi) air pressure
1.4, 14
D
Air Consumption Chart
0
20
40
60
80
100
012345
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
AIR CONSUMPTION
20 40 60 80
CPM
100
3.8 7.6 11.4 15.2 19.0
GPM
l/min
2.800
CFMm
3
/min
0.56
1.12
1.68
A
B
C
To find Pump Air Consumption (m
3
/min or
CFM/min) at a specific delivery (liter/min or gpm)
and operating air pressure (MPa/bar/psi):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with
selected air consumption curve.
Curve slopes from right to left. Follow left to
scale and read air consumption.
A 1.25 MPa, 12.5 bar (180 psi) air pressure
B 0.7 MPa, 7 bar (100 psi) air pressure
C 0.49 MPa, 4.9 bar (70 psi) air pressure
D 0.28 MPa, 2.8 bar (40 psi) air pressure
D
2.240