15307906
Performance Curves
0
25
50
75
100
125
150
012345
(3.8) (7.6) (11.4) (15.1) (18.9)
FLUID FLOW----gpm (lpm)
Test Fluid: No. 10 w eight oil at 75_ F (23.9_ C)
To find fluid outlet pressure at a s pecific fluid flow
and operating a ir pr essure:
1. Locate desired fluid flow along bottom of chart.
2. Follow vertical line up to intersection with
selected fluid outlet pressure curve (black).
3. Follow l eft to scale to read fluid out let p ressure.
To find pump air consumption at a specific fluid
flow and air pressure:
1. Locate desired flow along bottom o f chart.
2. Read vertical line up to i ntersection with
selected air consumption curve (gray).
2. Follow right to s cale t o read air consumption.
Air
Consumption
scfm
(m#/min)
KEY black curves=fluid outlet pressure
gray curves=air consumption
(0.34, 3.4)
(0.7, 7)
(0.51, 5.1)
(0.85, 8.5)
4
(0.112)
10
(0.280)
(1.0, 10.4)
2
(0.056)
6
8
(0.224)
A 40 psi (0.28 MPa, 2.8 bar) air pr essure
B 70 psi (0.48 MPa, 4.8 bar) air pr essure
C 100 psi (0.7 MPa, 7 bar) air pressure
D 150 psi (1.0 MPa, 10.4 bar) air pr essure
(0.17, 1.7)
B
C
D
(0.168)
A
B
D
C
A
Fluid
Outlet Pressure,
psi
(MPa, bar)