21
COOLING PERFORMANCE DATA GPH1348H41**
MODEL: GPH1348H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 45.1 46.7 51.2 - 44.0 45.6 50.0 - 43.0 44.5 48.8 - 41.9 43.5 47.6 - 39.8 41.3 45.2 - 36.9 38.2 41.9 -
S/T 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.83 0.69 0.48 - 0.85 0.71 0.49 - 0.89 0.74 0.51 - 0.89 0.75 0.52 -
Delta T181612 - 181612 - 181612 - 18 16 12 - 181612 - 171511 -
1800 KW 3.09 3.15 3.24 - 3.31 3.37 3.47 - 3.50 3.57 3.67 - 3.66 3.74 3.85 - 3.81 3.88 4.00 - 3.93 4.01 4.13 -
AMPS 13.6 13.8 14.2 - 14.5 14.7 15.1 - 15.5 15.8 16.2 - 16.4 16.7 17.2 - 17.2 17.6 18.1 - 18.1 18.5 19.0 -
HI PR 228 245 259 - 256 275 290 - 291 313 330 - 331 356 376 - 372 401 423 - 411 443 468 -
LO PR 109 116 127 - 116 123 134 - 120 128 139 - 126 134 146 - 132 141 154 - 137 145 159 -
MBh 43.8 45.4 49.7 - 42.7 44.3 48.5 - 41.7 43.2 47.4 - 40.7 42.2 46.2 - 38.7 40.1 43.9 - 35.8 37.1 40.7 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 -
Delta T191612 - 191612 - 191612 - 19 16 13 - 191612 - 181512 -
70 1600 KW 3.07 3.13 3.22 - 3.28 3.35 3.44 - 3.47 3.54 3.64 - 3.64 3.71 3.82 - 3.78 3.85 3.97 - 3.90 3.98 4.10 -
AMPS 13.5 13.7 14.1 - 14.4 14.6 15.0 - 15.4 15.7 16.1 - 16.2 16.6 17.0 - 17.1 17.5 18.0 - 18.0 18.3 18.9 -
HI PR 225 243 256 - 253 272 287 - 288 310 327 - 328 353 372 - 369 397 419 - 407 438 463 -
LO PR 108 115 126 - 114 122 133 - 119 126 138 - 125 133 145 - 131 139 152 - 135 144 157 -
MBh 40.4 41.9 45.9 - 39.5 40.9 44.8 - 38.5 39.9 43.7 - 37.6 38.9 42.7 - 35.7 37.0 40.5 - 33.1 34.3 37.5 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
Delta T191612 - 191713 - 191713 - 19 17 13 - 191713 - 181512 -
1400 KW 3.01 3.06 3.15 - 3.21 3.27 3.37 - 3.39 3.46 3.56 - 3.55 3.62 3.73 - 3.69 3.76 3.88 - 3.81 3.89 4.00 -
AMPS 13.2 13.4 13.8 - 14.0 14.3 14.7 - 15.0 15.3 15.7 - 15.9 16.2 16.6 - 16.7 17.1 17.5 - 17.5 17.9 18.4 -
HI PR 219 235 249 - 245 264 279 - 279 300 317 - 318 342 361 - 358 385 406 - 395 425 449 -
LO PR 105 112 122 - 111 118 129 - 115 123 134 - 121 129 141 - 127 135 147 - 131 140 153 -
MBh45.847.251.154.844.846.149.953.643.745.048.752.342.6
43.9
47.5 51.0 40.5 41.7 45.1 48.5 37.5 38.6 41.8 44.9
S/T 0.88 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.94 0.84 0.64 0.41 0.97
0.87
0.66 0.42 1.00 0.90 0.68 0.44 1.00 0.91 0.69 0.44
Delta T21191611211916112119161121
19
16 11 21 19 16 11 19 18 15 10
1800 KW 3.12 3.18 3.27 3.36 3.33 3.40 3.50 3.60 3.52 3.59 3.70 3.81 3.69
3.77
3.88 4.00 3.84 3.91 4.03 4.16 3.96 4.04 4.17 4.30
AMPS 13.7 13.9 14.3 14.7 14.6 14.9 15.3 15.7 15.6 15.9 16.4 16.9 16.5
16.8
17.3 17.9 17.4 17.7 18.2 18.8 18.3 18.6 19.2 19.8
HI PR 230 248 261 273 258 278 293 306 294 316 334 348 334
360
380 396 376 405 427 446 416 447 472 493
LO PR 110 118 128 137 117 124 136 144 121 129 141 150 127
136
148 158 134 142 155 165 138 147 160 171
MBh44.545.849.653.243.544.848.452.042.443.747.350.841.4
42.6
46.1 49.5 39.3 40.5 43.8 47.0 36.4 37.5 40.6 43.6
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93
0.83
0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T22201611222016112220161122
20
17 11 22 20 16 11 20 19 15 11
75 1600 KW 3.09 3.15 3.24 3.34 3.31 3.37 3.47 3.57 3.50 3.57 3.67 3.78 3.66
3.74
3.85 3.97 3.81 3.88 4.00 4.13 3.93 4.01 4.13 4.26
AMPS 13.6 13.8 14.2 14.6 14.5 14.7 15.1 15.6 15.5 15.8 16.2 16.7 16.4
16.7
17.2 17.7 17.2 17.6 18.1 18.7 18.1 18.5 19.0 19.6
HI PR 228 245 259 270 256 275 290 303 291 313 330 345 331
356
376 392 372 401 423 441 412 443 468 488
LO PR 109 116 127 135 116 123 134 143 120 128 139 149 126
134
147 156 132 141 154 164 137 145 159 169
MBh41.142.345.849.140.141.344.748.039.240.343.746.838.2
39.3
42.6 45.7 36.3 37.4 40.5 43.4 33.6 34.6 37.5 40.2
S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.59 0.38 0.89
0.80
0.60 0.39 0.93 0.83 0.63 0.40 0.93 0.84 0.63 0.41
Delta T22201711222017122220171222
21
17 12 22 20 17 12 21 19 16 11
1400 KW 3.03 3.08 3.17 3.26 3.23 3.30 3.39 3.49 3.42 3.49 3.59 3.70 3.58
3.65
3.76 3.88 3.72 3.79 3.91 4.03 3.84 3.92 4.04 4.16
AMPS 13.3 13.5 13.9 14.3 14.1 14.4 14.8 15.3 15.1 15.4 15.9 16.4 16.0
16.3
16.8 17.3 16.8 17.2 17.7 18.2 17.7 18.0 18.6 19.2
HI PR 221 238 251 262 248 267 282 294 282 303 320 334 321
346
365 381 361 389 411 428 399 430 454 473
LO PR 106 113 123 131 112 119 130 139 116 124 135 144 122
130
142 151 128 136 149 159 133 141 154 164
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.