19
COOLING PERFORMANCE DATA GPH1342H41**
MODEL: GPH1342H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 39.7 41.1 45.1 - 38.8 40.2 44.0 - 37.8 39.2 43.0 - 36.9 38.3 41.9 - 35.1 36.4 39.8 - 32.5 33.7 36.9 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.50 -
Delta T171511 - 181512 - 181512 - 18 15 12 - 181512 - 161411 -
1585 KW 2.82 2.88 2.96 - 3.02 3.08 3.17 - 3.20 3.26 3.36 - 3.35 3.42 3.52 - 3.48 3.55 3.66 - 3.59 3.67 3.78 -
AMPS 12.4 12.6 13.0 - 13.2 13.5 13.8 - 14.2 14.4 14.8 - 15.0 15.3 15.7 - 15.8 16.1 16.6 - 16.6 16.9 17.4 -
HI PR 235 253 267 - 264 284 300 - 300 323 341 - 342 368 388 - 384 414 437 - 425 457 483 -
LO PR 113 120 132 - 120 127 139 - 124 132 144 - 131 139 152 - 137 146 159 - 142 151 164 -
MBh 38.5 39.9 43.8 - 37.6 39.0 42.7 - 36.7 38.1 41.7 - 35.8 37.1 40.7 - 34.1 35.3 38.7 - 31.5 32.7 35.8 -
S/T 0.72 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.69 0.48 -
Delta T181612 - 181612 - 181612 - 19 16 12 - 181612 - 171511 -
70 1410 KW 2.80 2.86 2.94 - 3.00 3.06 3.15 - 3.17 3.24 3.33 - 3.32 3.39 3.49 - 3.45 3.52 3.63 - 3.57 3.64 3.75 -
AMPS 12.3 12.5 12.9 - 13.1 13.4 13.7 - 14.0 14.3 14.7 - 14.9 15.2 15.6 - 15.7 16.0 16.4 - 16.5 16.8 17.3 -
HI PR 233 251 265 - 261 281 297 - 297 320 338 - 338 364 385 - 381 410 433 - 421 453 478 -
LO PR 112 119 130 - 118 126 138 - 123 131 143 - 129 138 150 - 136 144 157 - 140 149 163 -
MBh 35.6 36.9 40.4 - 34.7 36.0 39.4 - 33.9 35.1 38.5 - 33.1 34.3 37.6 - 31.4 32.6 35.7 - 29.1 30.2 33.1 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T181612 - 191612 - 191612 - 19 16 12 - 191612 - 171511 -
1236 KW 2.74 2.80 2.88 - 2.93 2.99 3.08 - 3.10 3.16 3.26 - 3.25 3.31 3.41 - 3.37 3.44 3.55 - 3.48 3.55 3.66 -
AMPS 12.0 12.3 12.6 - 12.8 13.1 13.4 - 13.7 14.0 14.4 - 14.5 14.8 15.2 - 15.3 15.6 16.1 - 16.1 16.4 16.9 -
HI PR 226 243 257 - 253 273 288 - 288 310 327 - 328 353 373 - 369 397 420 - 408 439 464 -
LO PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 153 - 136 145 158 -
MBh 40.4 41.6 45.0 48.3 39.4 40.6 43.9 47.2 38.5 39.6 42.9 46.0 37.5
38.7
41.8 44.9 35.7 36.7 39.7 42.7 33.0 34.0 36.8 39.5
S/T 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95
0.85
0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43
Delta T20191511201915112019151121
19
16 11 20 19 15 11 19 18 14 10
1585 KW 2.85 2.90 2.98 3.07 3.04 3.10 3.20 3.29 3.22 3.29 3.38 3.49 3.38
3.44
3.55 3.66 3.51 3.58 3.69 3.81 3.62 3.70 3.81 3.93
AMPS 12.5 12.7 13.1 13.5 13.3 13.6 13.9 14.4 14.3 14.6 15.0 15.4 15.1
15.4
15.8 16.4 15.9 16.2 16.7 17.3 16.7 17.1 17.6 18.2
HI PR 238 256 270 282 267 287 303 316 303 326 344 359 345
372
392 409 388 418 441 460 429 462 488 509
LO PR 114 122 133 141 121 129 140 149 126 134 146 155 132
140
153 163 138 147 161 171 143 152 166 177
MBh 39.2 40.3 43.7 46.9 38.3 39.4 42.7 45.8 37.4 38.5 41.6 44.7 36.5
37.5
40.6 43.6 34.6 35.7 38.6 41.4 32.1 33.0 35.7 38.4
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90
0.81
0.61 0.39 0.94 0.84 0.63 0.41 0.95 0.85 0.64 0.41
Delta T21191611212016112120161121
20
16 11 21 20 16 11 20 18 15 10
75 1410 KW 2.82 2.88 2.96 3.05 3.02 3.08 3.17 3.27 3.20 3.26 3.36 3.46 3.35
3.42
3.52 3.63 3.48 3.55 3.66 3.78 3.59 3.67 3.78 3.90
AMPS 12.4 12.6 13.0 13.4 13.2 13.5 13.8 14.3 14.2 14.4 14.8 15.3 15.0
15.3
15.7 16.2 15.8 16.1 16.6 17.1 16.6 16.9 17.4 18.0
HI PR 235 253 267 279 264 284 300 313 300 323 341 356 342
368
388 405 385 414 437 456 425 457 483 504
LO PR 113 120 132 140 120 127 139 148 124 132 144 154 131
139
152 162 137 146 159 169 142 151 164 175
MBh 36.2 37.2 40.3 43.3 35.3 36.4 39.4 42.3 34.5 35.5 38.4 41.2 33.6
34.6
37.5 40.2 32.0 32.9 35.6 38.2 29.6 30.5 33.0 35.4
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87
0.78
0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T21201611222016112220161122
20
16 11 22 20 16 11 20 18 15 10
1236 KW 2.76 2.82 2.90 2.98 2.96 3.01 3.10 3.19 3.12 3.19 3.28 3.38 3.27
3.34
3.44 3.55 3.40 3.47 3.58 3.69 3.51 3.58 3.69 3.81
AMPS 12.1 12.4 12.7 13.1 12.9 13.2 13.5 13.9 13.8 14.1 14.5 15.0 14.6
14.9
15.3 15.8 15.4 15.7 16.2 16.7 16.2 16.5 17.0 17.6
HI PR 228 245 259 270 256 275 291 303 291 313 331 345 332
357
377 393 373 401 424 442 412 444 468 488
LO PR 110 117 128 136 116 123 135 144 121 128 140 149 127
135
147 157 133 141 154 164 137 146 160 170
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.