ProdUCt sPeCiFiCations
ProdUCt sPeCiFiCations
6 www.goodmanmfg.com SS-CPG36-72
P
rodUCt
s
PeCiFiCations
— CPG048 B m
odels
(
Cont
.)
CPG048
1151DXXX
CPG048
1153DXXX
CPG048
1153BXXX
CPG048
1154BXXX
CPG048
1157BXXX

Total BTU/h 45,500 45,500 45,500 45,500 45,500
Sensible BTU/h 35,000 35,000 35,000 35,000 35,000
SEER / EER 13.0 / 11.3 13.0 / 11.3 13.0 / 11.3 13.0 / 11.3 13.0 / 11.3
Decibels 78 78 78 78 78
AHRI Reference #s 4385062 4385063 4385063 4385064 4397608

Max. Input /Output kBTU/h 115 / 92 115 / 92 115 / 92 115 / 92 115 / 92
Low Input /Output kBTU/h 86.25 / 69 86.25 / 69 86.25 / 69 86.25 / 69 86.25 / 69
Steady State Eciency (AFUE) 80 80 80 80 80
Temperature Rise Range (°F) Hi / Low 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55
No. of Burners 5 5 5 5 5

Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive
Indoor Nominal CFM 1,600 1,600 1,600 1,600 1,600
Motor Speed Tap (Cooling) Medium Medium -- -- --
Indoor Motor FLA (Cooling) 2.87 2.87 3.8 1.9 2.3
Horsepower - RPM ½ - 1,000 ½ - 1,000 1.0 / 1,725 1.0 / 1,725 1½ / 1,725
Piston Size (Cooling) 0.076 0.076 0.076 0.076 0.076
Filter Size (#) 14 x 20 x 2 (4) 14 x 20 x 2 (4) 14 x 20 x 2 (4) 14 x 20 x 2 (4) 14 x 20 x 2 (4)
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾”
R-410A Refrigerant Charge Cir #1(oz.) 103 103 103 103 105
Evaporator Coil Face Area (²) 7.0 7.0 7.0 7.0 7.0
Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 4 / 16 4 / 16

# of Wheels (D” x W”) --- --- (1) 11 x 10 (1) 11 x 10 (1) 11 x 10
Motor Sheave / Blower Sheave --- --- VL44 X ⅝ / AK66 X 1
Belt --- --- AX55 AX55 AX55

Quanty of Condenser Fan Motors 1 1 1 1 1
Horsepower - RPM ¼ - 1,090 ¼ - 1,090 ¼ - 1,090 ¼ - 890 ¼ - 1,075
Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4
Outdoor Nominal CFM 3,800 3,800 3,800 3,800 3,800
Face Area (²) 17.0 17.0 17.0 17.0 17.0
Rows Deep/ Fins per Inch 1 / 24 1 / 24 1 / 24 1 / 24 1 / 24

Quanty / Stage 1 / Single 1 / Single 1 / Single 1 / Single 1 / Single
Type Scroll Scroll Scroll Scroll Scroll
Compressor RLA / LRA 19.9 / 109 13.1 / 83.1 13.1 / 83.1 6.1 / 41 4.4 / 33

Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-3-60 460-3-60 575-3-60
Outdoor Fan FLA 1.40 1.40 1.40 0.80 0.60
Total Unit Amps 24.1 17.4 18.3 8.8 7.3
Min. Circuit Ampacity¹ 29 21 22 10 8
Max. Overcurrent Protecon (amps)² 45 30 30 15 15
Power Supply Conduit Hole 1.125 1.125 1.125 1.125 1.125
Low-Voltage Conduit Hole ½” ½” ½” ½” ½”
 580 580 580 580 580
 605 605 605 605 605
¹WiresizeshouldbedeterminedinaccordancewithNationalElectricalCodes.Extensivewirerunswillrequirelargerwiresizes.
²MayusefusesorHACR-typecircuitbreakersofthesamesizeasnoted.