Goodman Mfg R-410A Air Conditioner User Manual


 
PACKAGE COOLING SPECIFICATIONS
8
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
WARNING
WARNING
GPC14[24-36]H41A*
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
(1)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
*
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
GPC1424H41* GPC1430H41* GPC1436H41*
COOLING
COOLING CAPACITY, BTUH 24,600 28,400 35,600
CAPACITY
SEER / EER 14.5 / 12.1 14.0 / 12.0 14.0 / 12.0
UNIT
VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60
ELECTRICAL
AMPS (TOTAL) 10.5 13.16 20.06
SPECIFICATION
MINIMUM CIRCUIT AMPACITY 12.5 15.6 24.2
MAXIMUM OVERCURRENT PROTECTION
(1)
20 25 40
COMPRESSOR
TYPE RECIP RECIP SCROLL
RATED LOAD AMPS 7.9 9.8 16.7
LOCKED ROTOR AMPS 41 55 79
CONDENSER
HORSEPOWER 1/6 1/4 1/4
FAN MOTOR
RPM 815 830 830
FULL LOAD AMPS 1.1 1.5 1.5
LOCKED ROTOR AMPS 1.7 3.0 3.0
CONDENSER FAN
BLADE DIAMETER (INCHES) / NUMBER OF BLADES 22 / 3 22 / 3 22 / 3
CONDENSER
FACE AREA - SQ. FT. 13.4 13.4 13.4
COIL
NUMBER OF ROWS 1 1 1
FINS PER INCH 24 24 24
EVAPORATOR
HORSEPOWER - NO. OF SPEEDS 1/2 - 5 1/2 - 5 1/2 - 5
BLOWER
FULL LOAD AMPS 1.5 1.86 1.86
MOTOR
LOCKED ROTOR AMPS NA NA NA
MOTOR SPEED TAP - COOLING T2 T2 T2
RPM 105010501050
EVAPORATOR
DIAMETER X WIDTH (INCHES) 10 X 8 10 X 8 10 X 8
BLOWER
HI EFFICIENCY COOLING CFM 850 1,050 1,200
5 TON NOMINAL COOLING CFM NA NA NA
FAN ONLY COOLING CFM 800 950 1,100
MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5
EVAPORATOR
FACE AREA - SQ. FT. 5.25 4.67 5.2
COIL
NUMBER OF ROWS 3 4 3
FINS PER INCH 16 16 14
GENERAL
FILTER SIZE - SQ. FT. * 20 x 20 x 1 20 x 25 x 1 25 x 25 x 1
INFORMATION
DRAIN SIZE (INCHES) 3/4" 3/4" 3/4"
EXPANSION DEVICE ORIFICE (0.057) ORIFICE (0.060) ORIFICE (0.065)
REFRIGERANT CHARGE R-410A (Oz.) 83 78 80
POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES
)
3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4
LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES) 1/2 1/2 1/2
SHIPPING WEIGHT LBS. 310 310 370
OPERATING WEIGHT LBS. 300 300 360