COOLING PERFORMANCE DATA GPC1430H41A*
MODEL: GPC1430H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26.5 27.5 30.1 - 25.9 26.8 29.4 - 24.6 25.5 27.9 - 22.8 23.6 25.9 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.50 -
Delta T161411 - 171411 - 171411 - 17 15 11 - 171411 - 151310 -
1180 KW 1.86 1.90 1.96 - 2.01 2.06 2.12 - 2.14 2.19 2.27 - 2.26 2.31 2.39 - 2.36 2.41 2.50 - 2.44 2.50 2.59 -
AMPS 7.7 7.9 8.1 - 8.3 8.5 8.7 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.1 10.3 10.7 - 10.7 10.9 11.3 -
HI PR 240 258 272 - 269 289 305 - 306 329 347 - 348 375 396 - 392 421 445 - 433 466 492 -
LO PR 111 119 129 - 118 125 137 - 122 130 142 - 128 137 149 - 135 143 156 - 139 148 162 -
MBh 27.0 28.0 30.7 - 26.4 27.4 30.0 - 25.8 26.7 29.3 - 25.1 26.1 28.5 - 23.9 24.7 27.1 - 22.1 22.9 25.1 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
Delta T171511 - 171511 - 171511 - 18 15 11 - 171511 - 161411 -
70 1050 KW 1.84 1.89 1.95 - 1.99 2.04 2.11 - 2.12 2.17 2.25 - 2.24 2.29 2.37 - 2.34 2.39 2.47 - 2.42 2.48 2.56 -
AMPS 7.6 7.8 8.0 - 8.2 8.4 8.6 - 8.9 9.1 9.3 - 9.4 9.6 10.0 - 10.0 10.2 10.6 - 10.6 10.8 11.2 -
HI PR 237 255 269 - 266 286 302 - 303 326 344 - 345 371 392 - 388 417 441 - 428 461 487 -
LO PR 110 117 128 - 117 124 135 - 121 129 141 - 127 135 148 - 133 142 155 - 138 147 160 -
MBh 24.9 25.8 28.3 - 24.4 25.2 27.7 - 23.8 24.6 27.0 - 23.2 24.0 26.3 - 22.0 22.8 25.0 - 20.4 21.2 23.2 -
S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T171511 - 181512 - 181512 - 18 15 12 - 181512 - 161411 -
920 KW 1.80 1.84 1.90 - 1.94 1.99 2.05 - 2.07 2.12 2.19 - 2.18 2.23 2.31 - 2.28 2.33 2.41 - 2.36 2.41 2.50 -
AMPS 7.4 7.6 7.8 - 8.0 8.2 8.4 - 8.6 8.8 9.1 - 9.2 9.4 9.7 - 9.7 10.0 10.3 - 10.3 10.5 10.9 -
HI PR 230 248 261 - 258 278 293 - 294 316 334 - 334 360 380 - 376 405 427 - 416 447 472 -
LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 138 150 - 134 142 155 -
MBh 28.3 29.1 31.5 33.9 27.6 28.5 30.8 33.1 27.0 27.8 30.1 32.3 26.3
27.1
29.3 31.5 25.0 25.8 27.9 29.9 23.2 23.9 25.8 27.7
S/T 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95
0.85
0.64 0.41 0.98 0.88 0.67 0.43 0.99 0.89 0.67 0.43
Delta T19181410191815101918151019
18
15 10 19 18 14 10 18 16 14 9
1180 KW 1.88 1.92 1.98 2.05 2.03 2.07 2.14 2.22 2.16 2.21 2.29 2.36 2.28
2.33
2.41 2.49 2.38 2.43 2.52 2.61 2.47 2.52 2.61 2.70
AMPS 7.87.98.28.58.38.58.89.19.09.29.59.89.6
9.8
10.1 10.5 10.2 10.4 10.7 11.1 10.8 11.0 11.4 11.8
HI PR 242 260 275 287 272 292 309 322 309 332 351 366 352
378
400 417 396 426 450 469 437 470 497 518
LO PR 113 120 131 139 119 126 138 147 124 131 143 153 130
138
151 161 136 145 158 168 141 150 163 174
MBh 27.5 28.3 30.6 32.9 26.8 27.6 29.9 32.1 26.2 27.0 29.2 31.3 25.6
26.3
28.5 30.6 24.3 25.0 27.1 29.0 22.5 23.2 25.1 26.9
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90
0.81
0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T20181510201815102019151020
19
15 11 20 18 15 10 19 17 14 10
75 1050 KW 1.86 1.90 1.96 2.03 2.01 2.06 2.12 2.20 2.14 2.19 2.27 2.34 2.26
2.31
2.39 2.47 2.36 2.41 2.50 2.58 2.44 2.50 2.59 2.68
AMPS 7.77.98.18.48.38.58.79.08.99.19.49.89.5
9.7
10.0 10.4 10.1 10.3 10.7 11.0 10.7 10.9 11.3 11.7
HI PR 240 258 272 284 269 289 305 319 306 329 347 362 348
375
396 413 392 422 445 464 433 466 492 513
LO PR 111 119 129 138 118 125 137 146 122 130 142 151 128
137
149 159 135 143 156 167 139 148 162 172
MBh 25.4 26.1 28.3 30.3 24.8 25.5 27.6 29.6 24.2 24.9 26.9 28.9 23.6
24.3
26.3 28.2 22.4 23.1 25.0 26.8 20.8 21.4 23.1 24.8
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.76 0.57 0.37 0.87
0.78
0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T20191510201915112019151121
19
16 11 20 19 15 11 19 17 14 10
920 KW 1.81 1.85 1.92 1.98 1.96 2.00 2.07 2.14 2.09 2.14 2.21 2.28 2.20
2.25
2.33 2.41 2.30 2.35 2.43 2.52 2.38 2.44 2.52 2.61
AMPS 7.57.77.98.28.18.28.58.88.78.99.29.59.3
9.5
9.8 10.1 9.8 10.1 10.4 10.7 10.4 10.6 11.0 11.4
HI PR 232 250 264 275 261 281 296 309 297 319 337 351 338
363
384 400 380 409 432 450 420 452 477 498
LO PR 108 115 126 134 114 121 133 141 119 126 138 147 125
133
145 154 131 139 152 162 135 144 157 167
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.