COOLING PERFORMANCE DATA GPC1436H41A*
MODEL: GPC1436H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 ±2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 9 ±2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 34.9 36.2 39.6 - 34.1 35.3 38.7 - 33.3 34.5 37.8 - 32.5 33.6 36.9 - 30.8 32.0 35.0 - 28.6 29.6 32.4 -
S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.48 - 0.87 0.72 0.50 - 0.87 0.73 0.51 -
Delta T181612 - 181612 - 181612 - 18 16 12 - 181612 - 171511 -
1349 KW 2.33 2.38 2.45 - 2.51 2.57 2.65 - 2.67 2.73 2.82 - 2.81 2.88 2.97 - 2.93 3.00 3.10 - 3.04 3.11 3.21 -
AMPS 10.5 10.8 11.0 - 11.3 11.5 11.8 - 12.1 12.3 12.7 - 12.8 13.1 13.4 - 13.5 13.8 14.2 - 14.2 14.5 14.9 -
HI PR 238 256 271 - 267 288 304 - 304 327 345 - 346 372 393 - 389 419 442 - 430 463 489 -
LO PR 107 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 - 29.9 31.0 34.0 - 27.7 28.7 31.5 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
Delta T191612 - 191713 - 191713 - 19 17 13 - 191612 - 181512 -
70 1200 KW 2.31 2.36 2.43 - 2.49 2.54 2.63 - 2.65 2.71 2.80 - 2.79 2.85 2.95 - 2.91 2.97 3.07 - 3.01 3.08 3.18 -
AMPS 10.5 10.7 11.0 - 11.2 11.4 11.7 - 12.0 12.2 12.6 - 12.7 12.9 13.3 - 13.4 13.7 14.1 - 14.1 14.4 14.8 -
HI PR 236 254 268 - 265 285 301 - 301 324 342 - 343 369 389 - 386 415 438 - 426 458 484 -
LO PR 106 113 124 - 112 120 131 - 117 124 136 - 123 131 143 - 129 137 149 - 133 142 155 -
MBh 31.3 32.4 35.5 - 30.5 31.6 34.7 - 29.8 30.9 33.8 - 29.1 30.1 33.0 - 27.6 28.6 31.4 - 25.6 26.5 29.1 -
S/T 0.70 0.58 0.41 - 0.73 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.67 0.46 - 0.80 0.67 0.47 -
Delta T191713 - 191713 - 191713 - 20 17 13 - 191713 - 181612 -
1052 KW 2.25 2.30 2.37 - 2.43 2.48 2.56 - 2.58 2.64 2.73 - 2.72 2.78 2.87 - 2.84 2.90 3.00 - 2.94 3.00 3.10 -
AMPS 10.2 10.4 10.7 - 10.9 11.1 11.4 - 11.7 11.9 12.3 - 12.4 12.6 13.0 - 13.1 13.3 13.7 - 13.7 14.0 14.4 -
HI PR 229 246 260 - 257 276 292 - 292 314 332 - 332 358 378 - 374 402 425 - 413 445 470 -
LO PR 103 110 120 - 109 116 127 - 113 121 132 - 119 127 138 - 125 133 145 - 129 137 150 -
MBh 35.5 36.5 39.5 42.4 34.7 35.7 38.6 41.4 33.8 34.8 37.7 40.5 33.0
34.0
36.8 39.5 31.4 32.3 34.9 37.5 29.0 29.9 32.4 34.7
S/T 0.87 0.77 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95
0.85
0.64 0.41 0.99 0.88 0.67 0.43 0.99 0.89 0.67 0.43
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
1349 KW 2.35 2.40 2.47 2.56 2.53 2.59 2.67 2.76 2.69 2.75 2.84 2.94 2.84
2.90
3.00 3.10 2.96 3.03 3.13 3.24 3.06 3.13 3.24 3.35
AMPS 10.6 10.8 11.1 11.5 11.3 11.6 11.9 12.3 12.2 12.4 12.8 13.2 12.9
13.2
13.5 14.0 13.6 13.9 14.3 14.8 14.3 14.6 15.1 15.6
HI PR 241 259 273 285 270 290 307 320 307 330 349 364 350
376
397 414 393 423 447 466 435 468 494 515
LO PR 109 116 126 134 115 122 133 142 119 127 138 147 125
133
145 155 131 140 152 162 136 144 158 168
MBh 34.4 35.5 38.4 41.2 33.6 34.6 37.5 40.2 32.8 33.8 36.6 39.3 32.0
33.0
35.7 38.3 30.4 31.3 33.9 36.4 28.2 29.0 31.4 33.7
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.78 0.59 0.38 0.91
0.81
0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T22201611222017112220171122
20
17 12 22 20 17 11 20 19 15 11
75 1200 KW 2.33 2.38 2.45 2.54 2.51 2.57 2.65 2.74 2.67 2.73 2.82 2.92 2.81
2.88
2.97 3.07 2.93 3.00 3.10 3.21 3.04 3.11 3.21 3.32
AMPS 10.5 10.8 11.0 11.4 11.3 11.5 11.8 12.2 12.1 12.3 12.7 13.1 12.8
13.1
13.4 13.9 13.5 13.8 14.2 14.7 14.2 14.5 14.9 15.4
HI PR 238 256 271 282 267 288 304 317 304 327 345 360 346
373
393 410 389 419 443 462 430 463 489 510
LO PR 107 114 125 133 114 121 132 140 118 126 137 146 124
132
144 153 130 138 151 161 134 143 156 166
MBh 31.8 32.7 35.4 38.0 31.1 32.0 34.6 37.1 30.3 31.2 33.8 36.3 29.6
30.4
33.0 35.4 28.1 28.9 31.3 33.6 26.0 26.8 29.0 31.1
S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.87
0.78
0.59 0.38 0.91 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T22201712222117122221171223
21
17 12 22 21 17 12 21 19 16 11
1052 KW 2.27 2.32 2.39 2.47 2.45 2.50 2.58 2.67 2.60 2.66 2.75 2.84 2.74
2.80
2.90 2.99 2.86 2.92 3.02 3.12 2.96 3.03 3.13 3.24
AMPS 10.3 10.5 10.8 11.1 11.0 11.2 11.5 11.9 11.8 12.0 12.4 12.8 12.5
12.7
13.1 13.5 13.2 13.4 13.8 14.3 13.8 14.1 14.6 15.0
HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336
361
382 398 378 407 429 448 417 449 474 495
LO PR 104 111 121 129 110 117 128 136 114 122 133 142 120
128
140 149 126 134 146 156 130 139 151 161
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions