COOLING PERFORMANCE DATA GPC1430H41A*
MODEL: GPC1430H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection ARI 95 test conditions. Design Superheat 10 ± 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 28.8 29.4 31.4 33.6 28.1 28.7 30.7 32.8 27.5 28.1 30.0 32.1 26.8 27.4 29.3 31.3 25.5 26.0 27.8 29.7 23.6 24.1 25.7 27.5
S/T 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.82 0.62 1.00 1.00 0.83 0.62
Delta T21201814222118142121181421 21 18 142020181418191713
1180 KW 1.89 1.93 2.00 2.07 2.04 2.09 2.16 2.23 2.18 2.23 2.30 2.38 2.30 2.35 2.43 2.52 2.40 2.46 2.54 2.63 2.49 2.55 2.63 2.73
AMPS 7.88.08.28.58.48.68.99.29.19.39.69.99.7 9.9 10.210.610.310.510.811.210.911.111.511.9
HI PR 244 263 278 290 274 295 312 325 312 336 354 370 355 382 404 421 400 430 454 474 442 475 502 523
LO PR 114 121 132 141 120 128 139 149 125 133 145 154 131 139 152 162 137 146 160 170 142 151 165 176
MBh 28.0 28.6 30.5 32.6 27.3 27.9 29.8 31.9 26.7 27.2 29.1 31.1 26.0 26.6
28.4
30.4 24.7 25.3 27.0 28.8 22.9 23.4 25.0 26.7
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 0.99 0.93
0.76
0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59
Delta T22211815222119152221191523 22
19
15 22 21 19 15 20 20 17 14
80 1050 KW 1.88 1.92 1.98 2.05 2.03 2.07 2.14 2.22 2.16 2.21 2.29 2.36 2.28 2.33
2.41
2.49 2.38 2.43 2.52 2.61 2.47 2.52 2.61 2.70
AMPS 7.87.98.28.58.38.58.89.19.09.29.59.89.6 9.8
10.1
10.5 10.2 10.4 10.7 11.1 10.8 11.0 11.4 11.8
HI PR 242 260 275 287 272 292 309 322 309 332 351 366 352 379
400
417 396 426 450 469 437 470 497 518
LO PR 113 120 131 139 119 126 138 147 124 131 144 153 130 138
151
161 136 145 158 168 141 150 163 174
MBh 25.8 26.4 28.2 30.1 25.2 25.8 27.5 29.4 24.6 25.1 26.9 28.7 24.0 24.5 26.2 28.0 22.8 23.3 24.9 26.6 21.1 21.6 23.1 24.7
S/T 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
Delta T22221915232219152322191523 22 19 152322191521201814
920 KW 1.83 1.87 1.93 2.00 1.98 2.02 2.09 2.16 2.11 2.15 2.23 2.30 2.22 2.27 2.35 2.43 2.32 2.37 2.45 2.54 2.40 2.46 2.54 2.63
AMPS 7.6 7.7 8.0 8.2 8.1 8.3 8.6 8.9 8.8 9.0 9.3 9.6 9.3 9.6 9.9 10.2 9.9 10.1 10.5 10.8 10.5 10.7 11.1 11.5
HI PR 235 253 267 278 263 283 299 312 300 322 340 355 341 367 388 404 384 413 436 455 424 456 482 503
LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 140 153 163 136 145 159 169
NOTE: Shaded area reflects AHRI rating conditions
MBh 29.3 29.9 31.3 33.4 28.6 29.2 30.6 32.6 27.9 28.5 29.8 31.8 27.3 27.8 29.1 31.1 25.9 26.4 27.7 29.5 24.0 24.5 25.6 27.3
S/T 0.99 0.96 0.87 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 0.99 0.81
Delta T23222118222321182222211821 22 22 192021211819192017
1180 KW 1.91 1.95 2.01 2.08 2.06 2.11 2.18 2.25 2.20 2.25 2.32 2.41 2.32 2.37 2.45 2.54 2.42 2.48 2.56 2.65 2.51 2.57 2.66 2.75
AMPS 7.9 8.1 8.3 8.6 8.5 8.7 8.9 9.3 9.2 9.4 9.7 10.0 9.8 10.0 10.3 10.7 10.4 10.6 10.9 11.3 10.9 11.2 11.6 12.0
HI PR 247 266 281 293 277 298 315 328 315 339 358 373 359 386 408 425 404 434 459 478 446 480 507 529
LO PR 115 122 133 142 121 129 141 150 126 134 146 156 132 141 154 164 139 148 161 172 144 153 167 178
MBh 28.5 29.0 30.4 32.4 27.8 28.3 29.7 31.7 27.1 27.7 29.0 30.9 26.5 27.0 28.3 30.1 25.1 25.6 26.8 28.6 23.3 23.7 24.9 26.5
S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
Delta T24232219242422192424221923 24 22 192222221920212118
85 1050 KW 1.89 1.93 2.00 2.07 2.04 2.09 2.16 2.23 2.18 2.23 2.30 2.38 2.30 2.35 2.43 2.52 2.40 2.46 2.54 2.63 2.49 2.55 2.63 2.73
AMPS 7.88.08.28.58.48.68.99.29.19.39.69.99.7 9.9 10.210.610.310.510.811.210.911.111.511.9
HI PR 244 263 278 290 274 295 312 325 312 336 354 370 355 382 404 421 400 430 454 474 442 475 502 523
LO PR 114 121 132 141 120 128 139 149 125 133 145 154 131 139 152 162 137 146 160 170 142 151 165 176
MBh 26.3 26.8 28.0 29.9 25.7 26.1 27.4 29.2 25.0 25.5 26.7 28.5 24.4 24.9 26.1 27.8 23.2 23.7 24.8 26.4 21.5 21.9 23.0 24.5
S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.91 0.74
Delta T24242219242423202424232024 24 23 202324221921222118
920 KW 1.84 1.89 1.95 2.01 1.99 2.04 2.11 2.18 2.12 2.17 2.25 2.32 2.24 2.29 2.37 2.45 2.34 2.39 2.47 2.56 2.42 2.48 2.56 2.65
AMPS 7.67.88.08.38.28.48.68.98.99.19.39.79.4 9.6 10.010.310.010.210.610.910.610.811.211.6
HI PR 237 255 269 281 266 286 302 315 303 326 344 359 345 371 392 408 388 417 441 459 428 461 487 508
LO PR 110 117 128 136 116 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171
* NOTE: Shaded area is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power
High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors)