COOLING PERFORMANCE DATA GSH140301A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: GSH140301A* / CA*F3636B6A* +TXV / MBR1200**-1 Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 28.4 29.0 31.0 33.1 27.7 28.3 30.3 32.4 27.1 27.7 29.6 31.6 26.4 27.0 28.8 30.8 25.1 25.6 27.4 29.3 23.2 23.8 25.4 27.1
S/T 1.000.940.760.571.000.970.790.591.001.000.810.611.001.000.840.631.001.000.870.651.001.000.880.65
Delta T212118142121181420211814202018151919181418181713
1214 KW 1.86 1.90 1.95 2.01 1.99 2.03 2.09 2.16 2.11 2.15 2.22 2.28 2.21 2.26 2.32 2.40 2.30 2.34 2.42 2.49 2.37 2.42 2.50 2.57
AMPS6.56.76.97.17.07.27.47.77.67.88.08.38.18.38.68.98.68.89.19.59.19.39.610.0
HI PR 140 151 159 166 157 169 178 186 179 192 203 212 203 219 231 241 229 246 260 271 253 272 287 300
LO PR 65 70 76 81 69 74 80 86 72 76 84 89 76 80 88 93 79 84 92 98 82 87 95 101
MBh 27.6 28.2 30.1 32.2 26.9 27.5 29.4 31.4 26.3 26.9 28.7 30.7 25.6 26.2 28.0 29.9 24.4 24.9 26.6 28.4 22.6 23.1 24.6 26.3
S/T 0.950.890.730.540.990.930.750.561.000.950.770.581.000.980.800.601.001.000.830.621.001.000.830.62
Delta T222119152322191522221915222219152121191519201814
80 1080 KW 1.85 1.89 1.94 2.00 1.98 2.02 2.08 2.14 2.09 2.14 2.20 2.27 2.19 2.24 2.31 2.38 2.28 2.33 2.40 2.47 2.35 2.40 2.48 2.55
AMPS6.56.66.87.17.07.17.47.67.57.78.08.38.08.28.58.88.58.89.09.49.09.39.69.9
HI PR 139 149 157 164 156 167 177 184 177 190 201 210 201 217 229 239 227 244 258 269 250 269 285 297
LO PR 65 69 75 80 68 73 80 85 71 76 83 88 75 80 87 92 78 83 91 97 81 86 94 100
MBh 25.4 26.0 27.8 29.7 24.9 25.4 27.1 29.0 24.3 24.8 26.5 28.3 23.7 24.2 25.8 27.6 22.5 23.0 24.6 26.2 20.8 21.3 22.7 24.3
S/T 0.920.860.700.520.950.890.730.540.980.920.750.561.010.940.770.571.050.980.800.601.050.990.800.60
Delta T232219152322191523221915232219152322191521201814
945 KW 1.811.851.901.951.941.972.032.092.052.092.152.212.142.192.252.322.232.272.342.412.302.352.422.49
AMPS6.36.46.66.96.86.97.27.47.37.57.88.07.88.08.38.68.38.58.89.18.89.09.39.6
HI PR 134 145 153 159 151 162 171 179 172 185 195 203 195 210 222 232 220 237 250 261 243 261 276 288
LO PR 63 67 73 78 66 71 77 82 69 73 80 85 73 77 84 90 76 81 88 94 79 84 91 97
MBh 28.9 29.5 30.8 32.9 28.2 28.8 30.1 32.1 27.6 28.1 29.4 31.4 26.9 27.4 28.7 30.6 25.5 26.0 27.3 29.1 23.7 24.1 25.3 26.9
S/T 1.001.000.910.741.001.000.940.771.001.000.970.791.001.001.000.811.001.001.000.841.001.001.000.85
Delta T222221182122221921212219202122191920211918181917
1214 KW 1.88 1.91 1.97 2.03 2.01 2.05 2.11 2.17 2.13 2.17 2.23 2.30 2.23 2.27 2.34 2.42 2.31 2.36 2.44 2.51 2.39 2.44 2.52 2.60
AMPS6.66.76.97.27.17.37.57.87.77.98.18.48.28.48.79.08.78.99.29.59.29.49.710.1
HI PR 141 152 161 168 159 171 180 188 180 194 205 214 205 221 234 244 231 249 263 274 255 275 290 303
LO PR 66 70 77 82 70 74 81 86 73 77 84 90 76 81 89 94 80 85 93 99 83 88 96 102
MBh 28.1 28.6 29.9 32.0 27.4 27.9 29.3 31.2 26.7 27.3 28.6 30.5 26.1 26.6 27.9 29.7 24.8 25.3 26.5 28.2 23.0 23.4 24.5 26.2
S/T 1.000.960.870.711.001.000.900.731.001.000.920.751.001.000.950.771.001.000.990.801.001.001.000.81
Delta T242322192324221923232219222323202122221920202118
85 1080 KW 1.86 1.90 1.95 2.01 1.99 2.03 2.09 2.16 2.11 2.15 2.22 2.28 2.21 2.26 2.32 2.40 2.30 2.34 2.42 2.49 2.37 2.42 2.50 2.57
AMPS6.56.76.97.17.07.27.47.77.67.88.08.38.18.38.68.98.68.89.19.59.19.39.610.0
HI PR 140 151 159 166 157 169 178 186 179 192 203 212 203 219 231 241 229 246 260 271 253 272 287 300
LO PR 65 70 76 81 69 74 80 86 72 76 84 89 76 80 88 93 79 84 92 98 82 87 95 101
MBh 25.9 26.4 27.6 29.5 25.3 25.8 27.0 28.8 24.7 25.2 26.4 28.1 24.1 24.6 25.7 27.4 22.9 23.3 24.4 26.1 21.2 21.6 22.6 24.1
S/T 0.960.930.840.681.000.960.870.711.000.990.890.721.001.000.920.751.001.000.950.771.001.000.960.78
Delta T242423202524232024242320232423202223232021212118
945 KW 1.821.861.911.971.951.992.052.112.062.102.172.232.162.202.272.342.242.292.362.432.322.362.442.51
AMPS6.46.56.76.96.87.07.27.57.47.67.88.17.98.18.48.78.48.68.99.28.99.19.49.7
HI PR 136 146 154 161 152 164 173 181 173 186 197 205 197 212 224 234 222 239 252 263 245 264 279 291
LO PR 64 68 74 79 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 84 92 98
Shaded area is ARI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)