Goodman Mfg GPC15 SEER Air Conditioner User Manual


 
PACKAGE COOLING SPECIFICATIONS
8
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
WARNING
WARNING
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
(1)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
*
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
GPC15[24-48]M41A*
GPC1524M41* GPC1530M41* GPC1536M41* GPC1542M41* GPC1548M41*
COOLING
COOLING CAPACITY, BTUH 24,000 28,000 35,000 40,000 45,500
CAPACITY
SEER / EER 14.5 / 12. 0 14.5 / 12. 0 14.5 / 12. 0 14.5 / 12. 0 15.0 / 12.0
UNIT
VOLTAGE (NAMEPLATE) 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
ELECTRICAL
AMPS 15.8 17.5 20.1 22.2 24.2
SPECIFICATION
MIN CIRCUIT AMPACITY 19.0 21.0 24.2 26.7 29.2
MAX OVERCURRENT PROTECTION 30 35 40 40 45
COMPRESSOR
TYPE SCROLL SCROLL SCROLL SCROLL SCROLL
RATED LOAD AMPS 12.8 14.1 16.7 17.9 19.9
LOCKED ROTOR AMPS 58.3 73.0 79.0 112.0 109.0
CONDENSER
HORSEPOWER 1/6 1/4 1/4 1/4 1/4
FAN MOTOR
RPM 815 837 837 1075 1075
FULL LOAD AMPS 1.1 1.5 1.5 1.4 1.4
LOCKED ROTOR AMPS 1.7 3.0 3.0 2.9 2.9
CONDENSER
BLADE DIAMETER (INCHES) 22 22 22 22 22
FAN
NUMBER OF BLADES 3 3 3 3 3
CONDENSER
FACE AREA (SQ. FT.) 12.33 12.33 12.33 15.38 15.38
COIL
NUMBER OF ROWS 122 2 2
FINS PER INCH 24 16 16 16 16
EVAPORATOR
HORSEPOWER - NO. OF SPEEDS 1/2 - 5 1/2 - 5 1/2 - 5 3/4 - 5 3/4 - 5
BLOWER
FULL LOAD AMPS 1.9 1.9 1.9 2.9 2.9
MOTOR
LOCKED ROTOR AMPS --- --- --- --- ---
MOTOR SPEED TAP-COOLING X-13 T2 T2 T2 T2 T2
RPM 1,050 1,050 1,050 1,050 1,050
EVAPORATOR
DIAMETER X WIDTH (INCHES) 10 x 9 10 x 9 10 x 9 10 x 9 10 x 9
BLOWER
RATED SCFM COOLING 850 1,050 1,150 1,350 1,350
MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 0.5 0.5
EVAPORATOR
FACE AREA (SQ. FT.) 4.52 4.52 4.52 6.17 6.17
COIL
NUMBER OF ROWS 334 4 4
FINS PER INCH 16 16 14 14 14
GENERAL
FILTER SIZE * 25 x 25 x 1 25 x 25 x 1 25 x 25 x 1 (2) 20 x 20 x 1 (2) 20 x 20 x 1
INFO RMATION
DRAIN SIZE (INCHES) 3/4" 3/4" 3/4" 3/4" 3/4"
EXPANSION DEVICE 0.057 0.065 0.068 0.072 0.076
REFRIGERANT CHARGE R410A (OZS.) 80 100 115 140 170
POWER SUPPLY
CONDUIT KNOCKOUT SIZE (INCHES)
3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4
LOW VOLTAGE
CONDUIT KNOCKOUT SIZE (INCHES)
1/2 1/2 1/2 1/2 1/2
SHIPPING WEIGHT (LBS.) 375 384 416 459 459