Goodman Mfg GPC15 SEER Air Conditioner User Manual


 
18
COOLING PERFORMANCE DATA GPC1542M41*
MODEL: GPC1542M41
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 7 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 41.2 42.7 46.8 - 40.2 41.7 45.7 - 39.3 40.7 44.6 - 38.3 39.7 43.5 - 36.4 37.7 41.3 - 33.7 35.0 38.3 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
Delta T181612 - 181612 - 191612 - 19 16 12 - 181612 - 171511 -
1519 KW 2.49 2.56 2.66 - 2.73 2.80 2.91 - 2.94 3.02 3.13 - 3.12 3.21 3.33 - 3.28 3.37 3.50 - 3.42 3.51 3.65 -
AMPS 12.1 12.4 12.7 - 12.9 13.2 13.6 - 13.9 14.2 14.6 - 14.7 15.0 15.4 - 15.5 15.8 16.3 - 16.3 16.7 17.1 -
HI PR 239 257 271 - 268 288 305 - 305 328 346 - 347 374 394 - 390 420 444 - 431 464 490 -
LO PR 112 119 130 - 118 126 137 - 123 131 143 - 129 137 150 - 135 144 157 - 140 149 163 -
MBh 40.0 41.5 45.4 - 39.1 40.5 44.4 - 38.1 39.5 43.3 - 37.2 38.6 42.3 - 35.3 36.6 40.1 - 32.7 33.9 37.2 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T191612 - 191713 - 191713 - 19 17 13 - 191713 - 181512 -
70 1350 KW 2.47 2.53 2.63 - 2.70 2.77 2.88 - 2.91 2.99 3.10 - 3.09 3.18 3.30 - 3.25 3.34 3.47 - 3.39 3.47 3.61 -
AMPS 12.0 12.3 12.6 - 12.8 13.1 13.5 - 13.8 14.1 14.5 - 14.6 14.9 15.3 - 15.4 15.7 16.2 - 16.2 16.5 17.0 -
HI PR 236 254 269 - 265 286 301 - 302 325 343 - 344 370 391 - 387 416 439 - 427 460 485 -
LO PR 111 118 129 - 117 125 136 - 122 129 141 - 128 136 148 - 134 143 156 - 139 147 161 -
MBh 36.9 38.3 41.9 - 36.1 37.4 41.0 - 35.2 36.5 40.0 - 34.3 35.6 39.0 - 32.6 33.8 37.1 - 30.2 31.3 34.3 -
S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.77 0.65 0.45 -
Delta T191713 - 201713 - 201713 - 20 17 13 - 191713 - 181612 -
1181 KW 2.39 2.46 2.55 - 2.62 2.69 2.80 - 2.82 2.90 3.01 - 3.00 3.08 3.20 - 3.15 3.24 3.36 - 3.28 3.37 3.50 -
AMPS 11.8 12.0 12.3 - 12.5 12.8 13.2 - 13.4 13.7 14.1 - 14.2 14.5 14.9 - 15.0 15.3 15.8 - 15.8 16.1 16.6 -
HI PR 229 247 261 - 257 277 292 - 293 315 333 - 333 359 379 - 375 404 426 - 414 446 471 -
LO PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
MBh 41.943.146.750.140.942.145.648.939.941.144.547.839.0
40.1
43.4 46.6 37.0 38.1 41.3 44.3 34.3 35.3 38.2 41.0
S/T 0.830.740.560.360.860.770.580.380.880.790.600.390.91
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.85 0.65 0.42
Delta T21191611212016112120161122
20
16 11 21 20 16 11 20 18 15 10
1519 KW 2.512.582.682.792.762.832.943.062.973.053.173.293.16
3.24
3.37 3.50 3.32 3.40 3.54 3.68 3.45 3.54 3.68 3.83
AMPS 12.2 12.5 12.8 13.2 13.0 13.3 13.7 14.1 14.0 14.3 14.7 15.2 14.8
15.1
15.6 16.1 15.6 16.0 16.4 17.0 16.4 16.8 17.3 17.9
HI PR 241 260 274 286 271 291 308 321 308 331 350 365 351
377
398 416 394 425 448 468 436 469 495 517
LO PR 113 120 131 140 119 127 139 148 124 132 144 154 130
139
151 161 137 145 159 169 141 150 164 175
MBh 40.741.945.348.739.740.944.347.538.839.943.246.437.8
39.0
42.2 45.3 35.9 37.0 40.1 43.0 33.3 34.3 37.1 39.8
S/T 0.790.710.540.350.820.740.560.360.840.750.570.370.87
0.78
0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T22201711222117122221171222
21
17 12 22 20 17 12 21 19 16 11
75 1350 KW 2.492.562.662.762.732.802.913.032.943.023.143.263.13
3.21
3.33 3.47 3.28 3.37 3.50 3.64 3.42 3.51 3.65 3.79
AMPS 12.1 12.4 12.7 13.1 12.9 13.2 13.6 14.0 13.9 14.2 14.6 15.0 14.7
15.0
15.4 15.9 15.5 15.8 16.3 16.8 16.3 16.7 17.1 17.7
HI PR 239 257 271 283 268 288 305 318 305 328 346 361 347
374
395 411 391 420 444 463 432 464 490 511
LO PR 112 119 130 138 118 126 137 146 123 131 143 152 129
137
150 160 135 144 157 167 140 149 163 173
MBh 37.538.741.844.936.737.840.943.935.836.939.942.834.9
36.0
38.9 41.8 33.2 34.2 37.0 39.7 30.7 31.6 34.3 36.8
S/T 0.770.680.520.330.790.710.540.350.810.730.550.350.84
0.75
0.57 0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.59 0.38
Delta T22211712232117122321171223
21
17 12 23 21 17 12 21 19 16 11
1181 KW 2.422.482.582.682.652.722.822.942.852.933.043.163.03
3.11
3.23 3.36 3.19 3.27 3.40 3.53 3.32 3.41 3.54 3.68
AMPS 11.9 12.1 12.4 12.8 12.6 12.9 13.3 13.7 13.6 13.8 14.2 14.7 14.3
14.6
15.1 15.6 15.1 15.4 15.9 16.4 15.9 16.2 16.7 17.3
HI PR 232 249 263 275 260 280 295 308 296 318 336 350 337
362
383 399 379 408 431 449 419 450 476 496
LO PR 109 116 126 134 115 122 133 142 119 127 139 148 125
133
145 155 131 140 152 162 136 144 158 168
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.