Goodman Mfg GPC14H Air Conditioner User Manual


 
Product SPecificationS
Product SPecificationS
SS-GPC14H www.goodmanmfg.com 3
SPecificationS
Models
GPC14
24H41AC
GPC14
30H41AA
GPC14
30H41AC
GPC14
36H41AA
GPC14
36H41AC
Cooling Capacity
Cooling Capacity (BTU/h) 24,600 28,400 28,400 35,600 35,600
Sensible BTU/h 18,200 21,600 21,600 27,100 27,100
SEER / EER 14.5 / 12.1 14.0 / 12.1 14.0 / 12.1 14.0 / 12.0 14.0 / 12.0
Decibels 76 76 76 78 78
AHRI Numbers 4635463 4635475 4635464 4635476 4635465
Evaporator Motor
Type EEM EEM EEM EEM EEM
Wheel (D x W) 10 x 8 10 x 8 10 x 8 10 x 8 10 x 8
Cooling CFM 850 1,050 1,050 1,200 1,200
Fan-Only CFM 800 950 950 1,100 1,100
RLA 1.5 1.86 1.86 1.86 1.86
No. of Speeds 5 5 5 5 5
Horsepower - RPM ½ - 1050 ½ - 1050 ½ - 1050 ½ - 1050 ½ - 1050
Evaporator Coil
Face Area (²) 5.25 5.25 5.25 5.2 5.2
Rows Deep/ Fins per Inch 3/ 16 3/ 16 3/ 16 3/ 14 3/ 14
Indoor Orice Size 0.057 0.062 0.062 0.068 0.068
Filter Size (”) 20 x 20 x 1 20 x 25 x 1 20 x 25 x 1 25 x 25 x 1 25 x 25 x 1
Drain Size (NPT) ¾" ¾" ¾" ¾" ¾"
Refrigerant Charge (oz.) 59 78 53 80 65
Condenser Fan / Coil
Horsepower - RPM 1/6 - 815 ¼ - 830 1/6 - 815 ¼ - 830 ¼ - 830
RLA/LRA 1.1 / 1.7 1.5 / 3.0 1.1 / 1.7 1.5 / 3.0 1.5 / 3.0
Fan Diameter/ # Fan Blades 22 / 2 22 / 3 22 / 2 22 / 3 22 / 3
Face Area (²) 12.3 13.4 12.3 13.4 12.3
Rows Deep/ Fins per Inch 1 / 26 1 / 24 1 / 26 1 / 24 1 / 26
Compressor
Quanty 1 1 1 1 1
Type Scroll Recip Scroll Scroll Scroll
Stage Single Single Single Single Single
Compressor RLA/LRA 13.5 / 58.3 9.8 / 55 12.8 / 64 16.7 / 79 16.7 / 79
Electrical Data
Voltage-Phase 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA 1.5 1.86 1.86 1.86 1.86
Outdoor Fan RLA 1.1 1.5 1.5 1.5 1.5
Total Unit Amps 16.1 13.16 15.76 20.06 20.06
Min. Circuit Ampacity¹ 19.5 15.6 19 24.2 24.2
Max. Overcurrent Protecon (amps)² 30 25 30 40 40
Ship Weight (lbs) 290 310 290 370 370
Operating Weight (lbs) 280 300 280 360 360
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.