Goodman Mfg CPKF Split System Heat Pump Heat Pump User Manual


 
p
rodUCt
S
peCifiCationS
p
rodUCt
S
peCifiCationS
SS-ICPKF www.goodmanmfg.com 5
4 www.goodmanmfg.com SS-ICPKF
expanded Cooling dataCpkf36-2m / arUf036-00*-2*

       

     71    71    71    71    71    71    71    71


MBh 34.2 35.5 38.9 - 33.4 34.7 38.0 - 32.7 33.8 37.1 - 31.2 32.4 35.5 - 29.1 30.1 33.0 - 26.9 27.9 30.5 - 25.1 26.0 28.5 - 24.4 25.3 27.7 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.84 0.70 0.49 - 0.85 0.71 0.49 - 0.9 0.7 0.5 - 0.88 0.73 0.51 -
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 - 15.6 13.5 10.2 - 15 13 10 -
kW 2.99 3.06 3.17 - 3.25 3.33 3.44 - 3.48 3.56 3.69 - 3.71 3.80 3.94 - 3.88 3.98 4.12 - 4.03 4.13 4.28 - 4.1 4.2 4.3 - 4.12 4.22 4.37 -
Amps 15.4 15.8 16.3 - 16.6 17.0 17.5 - 18.0 18.4 19.0 - 19.2 19.7 20.3 - 20.4 20.9 21.6 - 21.6 22.2 22.9 - 22.4 23.0 23.7 - 22.8 23.3 24.1 -
Hi PR 165 178 188 - 185 199 210 - 211 227 239 - 240 258 273 - 270 290 307 - 298 321 339 - 316.7 340.8 359.9 - 325 349 369 -
Lo PR 59 63 69 - 62 66 73 - 65 69 75 - 68 73 79 - 71 76 83 - 74 79 86 - 75.1 79.9 87.3 - 76 80 88 -

MBh 33.7 34.9 38.3 - 32.9 34.1 37.4 - 32.2 33.3 36.5 - 30.8 31.9 35.0 - 28.6 29.7 32.5 - 26.5 27.4 30.1 - 24.8 25.7 28.1 - 24.0 24.9 27.3 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.76 0.64 0.44 - 0.81 0.67 0.47 - 0.81 0.68 0.47 - 0.8 0.7 0.5 - 0.84 0.70 0.49 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 - 16.4 14.2 10.8 - 16 14 11 -
kW 2.97 3.04 3.15 - 3.23 3.30 3.42 - 3.46 3.54 3.66 - 3.69 3.78 3.91 - 3.86 3.95 4.10 - 4.01 4.10
4.25 - 4.1 4.2 4.3 - 4.09 4.19 4.34 -
Amps 15.3
15.7 16.2 - 16.5 16.9 17.4 - 17.9 18.3 18.9 - 19.1 19.6 20.2 - 20.3 20.8 21.5 - 21.5 22.0 22.7 - 22.3 22.8 23.6 - 22.6 23.2 23.9 -
Hi PR 164 176 186 - 184 198 209 - 209 225 238 - 238 256 271 - 268 288 305 - 296 319 337 - 314.5 338.5 357.4 - 322 347 366 -
Lo PR 59 62 68 - 62 66 72 - 64 69 75 - 68 72 79 - 71 76 82 - 73 78 85 - 74.6 79.4 86.7 - 75 80 87 -

MBh 32.0 33.2 36.4 - 31.3 32.4 35.5 - 30.6 31.7 34.7 - 29.2 30.3 33.2 - 27.2 28.2 30.9 - 25.2 26.1 28.6 - 23.5 24.4 26.7 - 22.8 23.6 25.9 -
S/T 0.65 0.54 0.38 - 0.68 0.56 0.39 - 0.69 0.58 0.40 - 0.73 0.61 0.42 - 0.77 0.65 0.45 - 0.78 0.65 0.45 - 0.8 0.7 0.5 - 0.80 0.67 0.46 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 - 16.9 14.7 11.1 - 17 14 11 -
kW 2.92 2.99 3.09 - 3.17 3.25 3.36 - 3.39 3.47 3.60 - 3.62 3.71 3.84 - 3.79 3.88 4.02 - 3.93 4.03 4.17 - 4.0 4.1 4.2 - 4.01 4.11 4.26 -
Amps 15.0 15.4 15.9 - 16.2 16.6 17.1 - 17.6 18.0 18.6 - 18.8 19.2 19.8 - 19.9 20.4 21.1 - 21.1 21.6 22.3 - 21.9 22.4 23.1 - 22.2 22.7 23.5 -
Hi PR 161 173 183 - 180 194 205 - 205 221 233 - 234 251 265 - 263 283 299 - 290 312 330 - 308.2 331.7 350.3 - 316 340 359 -
Lo PR 58 61 67 - 61 65 71 - 63 67 73 - 66 71 77 - 70 74 81 - 72 77 84 - 73 78 85 - 74 78 86 -


MBh 34.8 35.8 38.8 41.6 34.0 35.0 37.9 40.7 33.2 34.2 37.0 39.7 31.8 32.7 35.4 38.0 29.6 30.4 32.9 35.3 27.3 28.1 30.5 32.7 25.5 26.3 28.5 30.6 24.8 25.5 27.6 29.6
S/T 0.81 0.72 0.55 0.4 0.84 0.75 0.57 0.4 0.86 0.77 0.58 0.4 0.90 0.81 0.61 0.4 0.96 0.86 0.65 0.4 0.97 0.87 0.65
0.4 1.0 0.9 0.7 0.4 1.00 0.89 0.67 0.4
∆T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 15 11 20 19 15 11 19 17 14 9.8 18.0 16.6 13.6 9.4 18 16 13 9.2
kW 3.02 3.09 3.20 3.3 3.28 3.36 3.47 3.6 3.51 3.59 3.72 3.9 3.75 3.84 3.97 4.1 3.92 4.01 4.16 4.3 4.07 4.17 4.32 4.5 4.1 4.2 4.4 4.5 4.15 4.26 4.41 4.6
Amps 15.5
15.9 16.4 17.0 16.8 17.1 17.7 18.4 18.2 18.6 19.2 19.9 19.4 19.9 20.5 21.3 20.6 21.1 21.8 22.6 21.8 22.4 23.1 24.0 22.6 23.2 23.9 24.9 23.0 23.5 24.3 25.2
Hi PR 167 179 190 198 187 201 213 222 213 229 242 252 242 261 275 287 273 293 310 323 301 324 342 357 320 344 364 379 328 353 373 389
Lo PR 60 64 69 74 63 67 73 78 66 70 76 81 69 73 80 85 72 77 84 89 75 79 87 92 76 81 88 94 76 81 89 95

MBh 34.3 35.3 38.2 41.0 33.5 34.5 37.3 40.1 32.7 33.7 36.5 39.1 31.3  34.9 37.4 29.1 30.0 32.4 34.8 26.9 27.7 30.0 32.2 25.2 25.9 28.1 30.1 24.4 25.1 27.2 29.2
S/T 0.77 0.69 0.52 0.3 0.80 0.72 0.54 0.3 0.82 0.74 0.56 0.4 0.86  0.59 0.4 0.92 0.82 0.62 0.4 0.93 0.83 0.63 0.4 0.9 0.8 0.6 0.4 0.95 0.85 0.65 0.4
∆T 21 20 16 11 21 20 16 11 21 20 16 11 22  16 11 21 20 16 11 20 18 15 10.4 19.0 17.5 14.3 9.9 19 17 14 9.7
kW 3.00 3.07 3.18 3.3 3.26 3.33 3.45 3.6 3.49 3.57 3.70 3.8 3.72  3.95 4.1 3.89 3.99 4.13 4.3 4.04 4.14 4.29 4.4 4.1 4.2 4.4 4.5 4.13 4.23 4.38 4.5
Amps 15.4 15.8 16.3 16.9 16.7 17.0 17.6 18.2 18.1 18.5 19.1 19.8 19.3  20.4 21.1 20.5 21.0 21.7 22.5 21.7 22.2 23.0 23.8 22.5 23.0 23.8 24.7 22.8 23.4 24.2 25.1
Hi PR 166 178 188 196 186 200 211 220 211 227 240 250 241  274 285 271 291 308 321 299 322 340 355 318 342 361 377 326 350 370 386
Lo PR 59 63 69 73 63 67 73 78 65 69 76 81 68  79 85 72 76 83 89 74 79 86 92 75 80 88 93 76 81 88 94

MBh 32.6 33.5 36.3 39.0 31.8 32.8 35.5 38.1 31.1 32.0 34.6 37.2 29.7 30.6 33.1 35.6 27.7 28.5 30.8 33.1 25.6 26.3 28.5 30.6 23.9 24.6 26.7 28.6 23.2 23.9 25.9 27.7
S/T 0.74 0.66 0.50 0.3 0.77 0.69 0.52 0.3 0.79 0.70 0.53 0.3 0.83 0.74 0.56 0.4 0.88 0.79 0.59 0.4 0.89 0.79 0.60 0.4 0.9 0.8 0.6 0.4 0.91 0.82 0.62 0.4
∆T 22 20 16 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 11 21 19 15 10.7 19.6 18.0 14.8 10.2 19 18 14 10.0
kW 2.94 3.01 3.12 3.2 3.20 3.28 3.39 3.5 3.42 3.51 3.63 3.8 3.66 3.74 3.88 4.0 3.82 3.92 4.06 4.2 3.97 4.07 4.21 4.4 4.0 4.1 4.3 4.4 4.05 4.15 4.30 4.5
Amps 15.2
15.5 16.0 16.6 16.4 16.7 17.3 17.9 17.7 18.2 18.7 19.4 18.9 19.4 20.0 20.8 20.1 20.6 21.3 22.1 21.3 21.8 22.5 23.4 22.1 22.6 23.4 24.2 22.4 22.9 23.7 24.6
Hi PR 162 175 184 192 182 196 207 216 207 223 235 245 236 254 268 280 265 286 302 315 293 316 333 348 311 335 354 369 319 343 363 378
Lo PR 58 62 68 72 61 65 71 76 64 68 74 79 67 71 78 83 70 75 82 87 73 77 84 90 74 79 86 91 74 79 86 92
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions kW = Total system power
High and low pressures are measured at the liquid and sucon service valves. Amps = outdoor unit amps (comp.+fan)