Giant MP4130HT(C) Septic System User Manual


 
10
38. Reassemble the inlet valve
assembly in the reverse or-
der of step #7. Make cer-
tain all the components are
press fit together and that the
spring retainer (#54) is
slightly counter sunk in the
valve housing (#52). Grease
the o-ring (#53) and install it
on to the valve housing. Re-
install the entire inlet valve
assembly into the manifold
(#43). install the tension
plugs (#42A) and tighten.
39. Again lubricate the plungers
(29B) and slide the manifold
(#43) gently and evenly over
the plungers. Press the mani-
fold firmly into place against
the crankcase (#1). Install
the spring washer (#50A)
and tighten the manifold stud
nuts (#50) to 58 ft.lbs.
37. Place the entire discharge as-
sembly into discharge port
making certain the assembly
is properly seated. Install dis-
charge plug (#48) and hand
tighten.
Position Item# Description Torque Amount
10 01010 Screw, Crankcase Cover 125 ft-lbs.
17 07114 Hex Screw, Bearing Cover 125 in-lbs.
24A 07122 Hex Screw, Connecting Rod 250 in-lbs.
29C 07257 Bolt, Plunger 300 in-lbs.
50 07158 Nut, Manifold Stud 58 ft-lbs.
MP4130HT(C) TORQUE SPECIFICATIONS