Gianni Industries AD-425S Door User Manual


 
Copyright All Rights Reserved.
P-MU-AD425S Ver. A Publish:2008.07.11 Page: 6/ 20
The opening, closing and maintain -open time illustration table.
VM
(Opening and
Closing Time
Adjustment )
Opening and
Closing
Operating
Time
Total Opening and
Closing Time (VM+
Brake Time)
TC Time
(Maintain -open
time adjustment)
Maintain -open
time
(See Figure 4)
2 4.5
1
3 6.0
5
5 8.0
10
7 9.5
15
2
4.5 (With high torque
output)
20
3
6.0 (With high torque
output)
25
5
8.0 (With high torque
output)
30
7
9.5 (With high torque
output)
35
z For the wider door leaf, we suggest that you can extend the opening and closing time or
adjust the high torque output. For the 95cm~120cm door width, please refer the gray
region for setting. The high torque output enhanced the door stability.
z The opening operation based on 90° angle; however, there would be time difference from
the setting angles.
z Please refer to the below table for TC settings.
Door weight (kg)
Door width
(cm)
50 kg 60 kg 70 kg 80 kg 90 kg 100 kg
75 cm 20 s 20 s 22 s 22 s 25 s 28 s
85 cm 20 s 20 s 22 s 22 s 25 s 28 s
100 cm 22 s 22 s 24 s 24 s 27 s 30 s
120 cm 22 s 22 s 24 s 24 s 27 s 30 s