z Figure 11~13 showing an operator installation of a minimum door leaf width and a
maximum opening angle. The opening angle is recommended not excess to 120.
Figure 11
Figure 12 Figure 13
z Figure 14: Automatic door operator dimension
Figure 14
z Install AD-425S on an out-swing door, make sure that the distance between the header
and leaf is not more than 60mm, and the space between the header and Sliding Rail
mounting hole must be 60mm. (See Figure 15)
z Install AD-425S on an in-swing door, make sure that the distance between Square
Couplings and hinge is not more than 74mm , the space between header and the bottom
of AD-425S must be 23mm, and the space between header and Sliding Rail mounting
hole must be 39mm (See Figure 16)
Figure 15 Figure 16
z All dimensions and units are in millimeters unless otherwise specified.
z Make sure AD-425S performance is effectively; no extra door closer required.
z Warning: The AD-425S installation should regard the external and internal pressure
conditions. To assure the proper operation and the finest performance, please make a
regular check for your operator.