GE Z-6000 Water System User Manual


 
Z Series RO System by GE Osmonics
1.11.2 Flow Rates
1. Product flow rates based on the following conditions with product flow equal to
waste flow:
Operating Pressure: 200 - 250 PSI
Product Pressure: 1 PSI
pH: 6.5
Feed Water Temperature: 77°F (25°C)
Product Flow Rate
Model
Number
GPM LPM GPD LPD
Indirect Units
Z-9600 6.67 25.24 9,600 36,340
Z-12000 8.33 31.55 12,000 45,425
Z-14400 10 37.85 14,400 54,510
Direct Units
Z-6000 4.17 15.77 6,000 22,712
Z-8000 5.56 21.03 8,000 30,283
Z-10000 6.94 26.29 10,000 37,854
Z-12000 8.33 31.55 12,000 45,425
1.11.3 Electrical Requirements
1. RO Units
Voltage
Hertz Amps Phase Hp
230 60 24 1 5
208 60 20/27.5 3 5/7.5
230 60 16/24 3 5/7.5
460 60 8.5/12.5 3 5/7.5
2. Product Divert Controller
Receptacle Type Standard
Voltage 115 / 230~
Hertz 60 / 50
Amps 20
Phase Single
1238339b – 16Oct03 1 - 15 General Information