Entry Delay
Entry Delay is the amount of time the system gives you to disarm the system after enter-
ing the home (between 5 and 254 seconds). This is programmed by the installer. When
you enter your home you will hear beeps during the entry delay (see the table “Status
Beeps” of this manual to determine the meaning of panel/system beeps).
Your Entry Delay is set for ___ seconds.
Quick Exit
Note
The designated door may be
opened and closed once. If
you close the designated
door behind you when you
exit, you will have to disarm
the system upon reentering.
Leave the designated door
open while using the Quick
Exit feature.
The Quick Exit feature is used when someone wants to briefly leave while the home is
still armed (i.e. get the newspaper). This feature needs to be enabled by your installer.
When you press the Disarm button the panel will announce exit time on. This will allow
a designated exit door to be open for up to 2 minutes without triggering an alarm.
Latchkey
Latchkey is used to notify parents, via a numeric pager or remote phone, if children do
not arrive home at a predetermined time and disarm the system. For example, you set
the Latchkey time for 3:00 pm. If the system isn’t disarmed by that time a message is
sent to your numeric pager (see “Numeric Pager”) or remote phone.
Subdisarm
If your system includes 24-hour protection sensors on items such as gun or jewelry
cases, you must subdisarm the panel before accessing these areas to avoid causing an
alarm. Environmental sensors, such as smoke and carbon monoxide stay active at all
times.
¾
Arming Your System with Doors & Windows Closed
1. Close all doors and windows.
2. Press Arm Doors & Windows button.
3. Enter Access Code (if needed).
Panel announces, Doors and windows on, Arm Doors & Windows light will be lit and
the exit delay will begin.
¾
Arming Your System with Doors or Windows Open (Indirect Bypassing)
1. Close all doors and windows except the ones you wish to remain open.
2. Press Arm Doors & Windows button.
3. Enter Access Code (if needed).
Note
Any sensors that are
bypassed by the system will
NOT be protecting your
home.
Panel announces any protected doors or windows that are open. Any sensors that are
open when the system is armed will be bypassed automatically after exit. Arm Doors &
Windows light will be lit and the exit delay will begin.
¾
Arming Your System with No Entry Delay
Note
No Entry Delay can be used
in two ways. First, you can
use this feature when you’re
staying at home, after you’ve
armed the system (i.e. when
you’re asleep). Second, you
can use this when you’re
away from your home. To
avoid causing an alarm, you
must disarm the system with
a remote handheld touchpad
or keychain before entering
your home. Check with your
installer to find out how this
option is programmed.
1. Close all doors and windows.
2. Press Arm Doors & Windows button twice.
3. Enter Access Code (if needed).
Panel announces, Doors and windows on, no entry delay. Arm Doors & Windows light
will blink and the exit delay will begin.
¾
Arm Motion Sensors
1. Press Arm Motion Sensors button once.
2. Enter access code (if needed).