Zone Light The zone lights are “off” when everything is normal. A zone light will be “on” if the zone has
been bypassed. If a zone light is “flashing”, that zone is in alarm or has been faulted. If a zone
light is “flashing” rapidly, it means that the zone is in a trouble condition. Trouble conditions
are
Tamper Hardware Low Battery Loss of supervision
(A combination of Alarm/Fault and Tamper/Trouble will produce a rapid “flashing” light for a
short period of time, followed by a slow “flashing” light.)
EMERGENCY ACTIVATION KEYS
NOTES: You must hold these keys for 2 seconds to activate these functions. Your system may not be
programmed for these activation keys. You should press these keys only in an emergency situation that
requires response by emergency personnel. If your system is programmed for these functions, the following
reports can be sent.
Fire Key – This key can activate the fire alarm when pressed for two seconds. If your system is connected to
a monitoring center, an emergency report could be sent to that center.
Auxiliary Emergency Key – This key can activate the auxiliary alarm when pressed for two seconds. If your
system is connected to a monitoring center, an emergency report could be sent to that center.
Police (Panic/Hold-Up) Key - This key can sound a local audible alarm when pressed for two seconds. If
your system is connected to a monitoring center, an emergency report could be transmitted to that center.
NOTE: Some Panic/Hold-Up alarms are programmed to be silent at the protected site while reporting an
alarm to the monitoring center. Check with your installing company to determine how your security system will
respond to the Panic/Hold-Up activation.