OTHER KEYPAD FUNCTIONS
Setting the keypad tone
Step 1 Press the [r] key.
Step 2 Press the [0] key. Keypad is now in the “Adjust Tone” mode.
Step 3 Pressing the [1] key will make the keypad sounder go to higher tones, pressing the [2] key will
make the keypad sounder go to lower tones.
Step 4 When the desired tone is reached, press the [#] key to set this tone and exit
from the “Adjust Tone” mode.
Change partition (optional)
Step 1 Press the [r] key.
Step 2 Press the [1] key.
Step 3 Press a NUMBER key between 1 and 8 to change partitions momentarily.
Step 4 If no other key is pressed, it will go back to its standard partition in ten seconds.
Step 5 If another key is pressed, the system will remain in the new partition until no keys have been
pressed for 60 seconds.
View alarm memory
Step 1 Press the [r] key.
Step 2 Press the [3] key to display the zone(s) on the keypad that created the last alarm.
Step 3 The ALARM MEMORY feature will flash those zones that created alarms and will light steady
those zones that were bypassed during the last alarm.
Test function (optional)
If programmed, this function will perform a battery test, communicator test, and/or a siren test.
Step 1 Press [r] [4] [4]. The test will be performed as programmed.
Step 2 If the siren test is performed, enter a user code to silence the siren.
No alarms will be sent and no reports will be sent unless a communicator test is performed, at which
time a test signal will be sent.
NX-108/116/124E User manual Page 13 04/10/04