GE GXRV10ABL01 Water System User Manual


 
Fig. 4A.
Spacer
Mounting plate
Base
Hex nut
Lever
Spout
Faucet
stud
Large gasket
Compression nut
Metal washer
Tubing adapter
ASSEMBLED
Consumer SupportTroubleshooting TipsOperating InstructionsSafety Instructions Installation Instructions
15
Faucet Installation
Be sure there is room underneath the sink to make the
needed connections. Select one of the following places
to install the faucet:
IN an existing sink spray attachment or soap
dispenser hole.
IN a hole to be drilled in the sink top.
IN a hole to be drilled in the countertop,
next to the sink.
NOTE: Looking at Fig. 4B, be sure the faucet base will fit
flat against the surface at the selected location so the
gasket will seal.
If drilling is needed, make a 1-1/4 dia. hole.
Be sure to use the proper procedure for drilling
porcelain or stainless steel.
Place base on threaded stem (flange facing down).
Next, place large gasket on threaded stem, making
sure the stem and two barbed studs fit through the
gasket. Place spacer on stud (open end up) followed
by metal washer and hex nut (Fig. 4A).
Insert washer into tubing adapter. Securely tighten
to faucet stud.
Take the 27 length of 3/8 tubing and push one
end completely onto the 3/8 faucet barb fitting
(Fig. 4B).
Position the Reverse Osmosis system under the sink.
Referring to Fig. 5, on the next page, hang the
system on cabinet wall.
Route the 1/4tubing (marked “1⁄4 BARB ON
FAUCET”) and the 3/8 tubing (marked “FAUCET”)
up through the mounting hole:
Push one end of the 1/4 tubing onto the 1/4
barb on the faucet.
Using the compression nut, fasten the 3/8tubing
to the tubing adapter and tighten the nut. Make
sure the tubing is completely seated in the adapter.
Remove the short shipping tube and insert the spout
into the faucet body.
Lower the faucet assembly through the sink.
Under the counter, place the mounting plate above
spacer and securely tighten the hex nut.
9
8
7
b
a
6
5
4
3
2
1
Fig. 4B.
Faucet
NOTE: For ease of service and
maintenance, keep tubing
lengths long enough so removal
of the Reverse Osmosis system
from under the sink is possible.
Tubing adapter
Plastic washer
1/4 barb fitting
3/8 tubing,
27 long
3/8 barb fitting
3/8 tubing
marked FAUCET
1/4 tubing
marked 1/4 barb
Compression nut
To drain
From RO
From RO