GE GN75ENSRSA Water Heater User Manual


 
REMOTE CONTROLLER INSTALLATION (cont.)
MOUNTING THE CONTROLLER (cont.)
Thread the cable through the access hole at the base
of the unit and connect the wires to the controller
terminals on the bottom right-hand side of the PCB.
Secure the controller cable using the clamp provided.
Replace the plastic cover over the PCB, and then
replace the cover of the water heater.
12
11
10
19
Installation Instructions
CLEANING THE INLET FILTER
It is imperative that
control compartments,
burners and circulating
air passageways of the
appliance be kept clean.
CAUTION: Before
performing this action, first
remove power to the water
heater and be sure not to
stand near the discharge line of the pressure relief valve.
This will prevent a possible scald injury
.
Turn off and disconnect electrical power. Allow water
heater to cool.
Shut off water inlet.
Open hot water tap at nearest faucet.
Close outlet valve on unit.
Have a small pan or bucket ready to catch spilled
water.
Remove and clean the water inlet filter with a small
brush. If scale is present, clean in a white vinegar
solution.
Replace water inlet filter.
Remove the front panel by removing 4 screws.
8
7
6
5
4
3
2
1
Waterinlet
filter
Waterinlet
NOTE:Viewshown
isfromundertheunit.
CLEANING THE INLET FILTER (cont.)
Use pressurized air to remove dust from the main
burner, heat exchanger and fan blades. Do not use a
wet cloth or spray cleaners on the burner. Do not use
volatile substances such as benzene and thinners.
They may ignite or fade the paint.
Use soft dry cloth to wipe cabinet.
Open water valves.
Check for leaks.
Connect electrical power and turn on the unit.
13
12
11
10
9
INSTALLATION CHECKLIST
Ensure 120 Volts A.C. is connected to the unit and that
the circuit is turned on.
Verify the gas system is functioning correctly by
connecting your manometer to the gas pressure test port
on the unit (see page 11). Operate all gas appliances in
the facility. The inlet gas pressure on the unit MUST NOT
DROP BELOW that listed on the unit rating plate for the
gas type being used. A manometer can be used to check
the pressure.
Make sure you have cleaned the COLD water inlet filter
screen.
Inspect HOT (outlet) and COLD (inlet) water lines to ensure
they have not been crossed and are leak-free.
Ensure the manual gas valve packaged with the water
heater is installed in the gas supply line (see page 10).
Ensure the controller is installed and functioning.
Instruct the consumer on how to operate the controller.
Instructions are always supplied in the Owner’s Manual
(see page 18). A typical water temperature set point
is 120 degrees.
For instructions on operating the unit, refer to the Owner’s
Manual.