GE GN75ENSRSA Water Heater User Manual


 
Installation Instructions
ELECTRICAL CONNECTION
INFORMATION
WARNING To reduce the risk
of fire, electrical shock and personal injury:
The water heater must be electrically grounded
in accordance with local codes and ordinances
or, in the absence of local codes, in accordance
with the NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70, or the CANADIAN ELECTRICAL CODE,
CSA C22.1.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz,
and connected to a properly grounded branch
circuit, protected by a 15- or 20-amp circuit
breaker or time-delay fuse.
If electrical supply provided does not meet the
above specifications, it is recommended that a
licensed electrician install an approved outlet.
4
PCB
GROUND
TERMINAL
120VAC CONNECTION WIRES
(Black-Hot/White-Neutral)
Wire nuts
Inside unit
Electrical
disconnect
switch
Electrical
connection
Outside unit