N
L
BLS/E/20W/CMH
BLS/E/35W/CMH
BLS/E/20W/CMH/R
BLS/E/35W/CMH/R
BLS/E/70W/CMH
BLS/E/70W/CMH/R
BLS/E/150W/CMH
BLS/E/150W/CMH/R
Control gear and accessories
Electronic Ballasts
A range of GE electronic ballasts have been introduced to complement the 20, 35, 70 and 150W ConstantColor™
Ceramic Metal Halide lamps
Power controlled electronic ballasts suitable for operation of Ceramic Metal Halide lamps are available from various gear
manufacturers.
Advantages are:
• Good regulation against supply voltage variation
• Improved lamp colour consistency
• Elimination of lamp icker
• Reduced weight of control gear
• Reduced electrical power losses
• Ballast noise reduced/eliminated
• Single piece compact unit
• Reduced wiring complexity in the luminaire
Features
• Integral version with open terminals for embodiment into luminaire
• Remote version with terminal cover and cable strain relief for location outside the luminaire
• 50,000 hours service life under the specied conditions
• Reduced power consumption compared to electromagnetic circuits
• Reduced component count and simplied wiring compared to electromagnetic circuits
• Rapid and controlled power run-up
• Lamp life maximised by square-wave current and constant lamp power
• Excellent lamp colour stability throughout life
• Automatic lamp failure shut-down
• Timed restart after mains voltage interruption
• Immune to mains voltage variations
General Information
Watts Volts Description Mounting Weight Pack Qty Product Code
20
220-240
BLS/E/20W/CMHSMP
Integral 110 g 12 42387
20
220-240
BLS/E/20W/CMH
Integral 190 g 12 13032
20
220-240
BLS/E/20W/CMH/R
Remote 230 g 12 13034
35
220-240
BLS/E/35W/CMH
Integral 215 g 12 13035
35
220-240
BLS/E/35W/CMH/R
Remote 230 g 12 13036
70
220-240
BLS/E/70W/CMH
Integral 300 g 12 13040
70
220-240
BLS/E/70W/CMH/R
Remote 310 g 12 13047
150
220-240
BLS/E/150W/CMH
Integral 430 g 12 13050
150
220-240
BLS/E/150W/CMH/R
Remote 445 g 12 13053
System Performance
20W 35W 70W 150W
System Power
W 23.5 43 78 159
System
lm/W 72 79 79 88
Lumens*
lm 1700 3400 6200 14000
Lamp Power
W 20 39 72 146
Lamp Efficacy lm/W
85 87 86 96
Lamp Voltage Range
V 70…125 70…125 70…125 70…125
* Data shown relates to 3000K products. Please see lamp data sheets for performance of equivalent 4200K rated products.
Operating Characteristics 20W 20W 35W 70W 150W
Mains Voltage
V 220...240 220...240 220...240 220...240 220...240
Mains Current
A 0.19 0.10 0.18 0.33 0.69
Mains Frequency
Hz 50 50...60 50...60 50...60 50...60
Power Factor
> 0.55 > 0.95 > 0.95 > 0.95 > 0.95
Allowed Mains Voltage Range
V 198...264 198...264 198...264 198...264 198...264
Ignition Voltage*
kV < 3.5 < 2.5 < 2.5 < 2.5 < 2.5
Lamp Operating Frequency
Hz 133 150 150 150 150
Max Cable Capacitance
pF 1000 1000 3000 3000 3000
Max Lamp Distance**
m 2 10 25 25 25
Ambient Temperature Range
°C -20...+50 -20...+50 -20...+50 -20...+50 -20...+50
Maximum Case Temperature
°C 80 75 75 75 80
Thermal Cut-off on PCB
°C 110 110 110 110 110
* If a hot lamp or no lamp is detected the ballast will attempt to start the lamp after one minute, if not successful further attempts are made up to a maximum
of 4 times in 5 minute cycles, then if not successful the ballast will shut-down. The ballast is reset automatically by a supply interruption.
** Typical value if cable capacitance is below the specifi ed limit
Dimension
BLS/E/20W/
CMHSMP
BLS/E/20W/CMH
BLS/E/35W/CMH
BLS/E/70W/CMH BLS/E/20W/CMH/R
BLS/E/35W/CMH/R
BLS/E/70W/CMH/R
BLS/E/150W/CMH BLS/E/150W/CMH/R
Circuitry
Wire cross section: 0.75...2.5 mm
2
112,5
101,5
36 31
36
72
4,2
31
123
98
4,2
32,5
A
126
5,2
73
90
120
137
40
B
126
5,2
90
73
120
177
40
C
5,2
45,5
126
130
73
91
142,5
37
D
5,2
45,5
121
130
73
91
172
37
E
The ballasts comply with the relevant
parts of the following standards:
– RFI suppression EN 55015
– Harmonics EN 61000-3-2
– Immunity EN 61547
– Safety EN 60926/EN 60928/EN 61347
– Performance EN 60927/EN 60929
A