BUILD AND INSTALL THE
ZONELINE BASE PLATFORM
1. Construct a 23
1
⁄4″ min. x 23
1
⁄4″ min. square platform.
NOTE: The platform must have a load-bearing
capacity of 175 lbs. minimum.
1
Installation Instructions
18
WALL PLENUM AND ARCHITECTURAL LOUVER INSTALLATION
• Install the appropriate wall plenum through the exterior wall in accordance with the Installation Instructions
provided with the plenum.
IMPORTANT: The wall plenum is not designed to carry structural loads.
Proper wall header construction is required. The plenum requires proper
flashing, shim and caulk for a weather resistant installation.
Properly square and
level plenum.
Proper header for
structural support.
Apply proper caulking
and flashing.
Architectural
Louver—RAVAL1
Exterior/Outside Wall
Case
Wall Plenum
RAVWP6 – 6″D x 19
3
⁄4″W x 32″H
RAVWP8 – 8″D x 19
3
⁄4″W x 32″H
RAVWP12 – 12″D x 19
3
⁄4″W x 32″H
RAVWP15 – 15″D x 19
3
⁄4″W x 32″H
2. Place the platform in the utility closet with the
following clearance between it and the interior
surface of the walls/door/panel:
• 4″ min. from front of the case – Unit to be
installed through FRONT of case
• 5″ min. from front of the case – Unit to be
installed through SIDE of case
• 3″ min. from two sides of the case
3. Align the platform with the opening of
the wall plenum and secure to the floor
using appropriate brackets and bolts.
23
1
⁄4″ min.
23
1
⁄4″ min.
8″ min.
for drain
access
Cutout for drain
connection