GE 2800 Air Conditioner User Manual


 
8
Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions
Auxiliary controls on your Zoneline.
Auxiliary Controls—Terminal Connections
The auxiliary controls are located behind the
room cabinet beneath the access cover.
Remove the room cabinet. See the
To Remove the Room Cabinet section.
Remove the screw from the access cover.
To make wiring connections, insert the wires
into the bottom of the terminals and tighten
screws securely.
After all desired connections have been
made, replace the access cover and room
cabinet.
The owner is responsible for making all
connections and setting the appropriate
dip switches.
CAUTION:
Improper wiring may damage the Zoneline
electronics. No common busing is permitted.
Damage or erratic operation may result.
A separate wire pair must be run from each
separate controlling switch to each individual
Zoneline.
4
3
2
1
External Fan
Central Desk Control
Common - Ground
White - Heater
Yellow - Compressor
Black - Solenoid
Green - High Speed Fan
Green - Low Speed Fan
Red - 24 V AC only