GE 263 Water System User Manual


 
UltraMax System Configurations 43
Rev A
UltraMax System Configurations
Upon initial start-up of the UltraMax controller, the software will request a
pre-determined model number. This model number populates the default
values within the controller, allowing for quick and easy set-up of the
software without entering several levels of data. The table below shows
the pre-determined model numbers for the controller and the associated
primary valve functions for each number.
Use the UP and DOWN buttons to scroll through the available model
numbers. Press the SET button to select the number and move to the
standard programming value.
Controller Reset:
If the incorrect model number is accidentally selected for the controller,
you can easily reset the controller to the factory default mode. When the
controller is in normal operating mode showing the time of day, perform
the following steps.
1. Press the DOWN and SET buttons simultaneously and hold for 5
seconds.
2. After 5 seconds the controller will go blank. Release the buttons and
the controller will scroll "MODEL NUMBER " and the selected model will
be displayed.
3. If the number is correct, wait 30 seconds and the controller will
automatically go back to normal operation mode.
4. If the model number is incorrect, press and hold the SET button for 5
seconds. This will default the controller back to the factory default
setting. The controller will scroll "MODEL NUMBER " and the factory
model number will begin flashing, meaning it can be changed. USe the
UP or DOWN buttons to scroll to the correct model number. Select that
number by pressing the SET button.
Model
Number
System Description
Operation
Type
System
Capacity
Salt
Amount
10 1.0 cu ft Conditioner 268 Valve 15 Kgrains 3.0 lbs
15 1.5 cu ft Conditioner 268 Valve 23 Kgrains 4.5 lbs
20 2.0 cu ft Conditioner 268 Valve 31 Kgrains 6.0 lbs
93 Generic Filter 263 Valve N/A N/A
98 Generic Conditioner 268 Valve 25 Kgrains 9.0 lbs