GE 2500 Air Conditioner User Manual


 
Installation Instructions
14
HOW TO CONNECT
1 Remove the room cabinet.
2 Connect to electrical power.
3 See the special instructions below for applicable
supply voltages.
4 Reinstall the room cabinet.
230/208 VOLT
ELECTRICAL SUPPLY
All wiring, including installation of the receptacle,
must be in accordance with the NEC and local codes,
ordinances and regulations.
This unit is equipped with a line cord for appropriate
amperage wall receptacle. See below.
Tandem
15 Amp.
230/208 volt receptacle configuration.
Perpendicular
20 Amp.
Large Tandem
30 Amp.
Order Kit RAK4002A for 230/208 volt
direct connection.
230/208 volt models may be installed using one of
the following electrical subbases:
Electrical subbases provide a flexible enclosure for
direct connection or enclosed receptacles.
The instructions provided with the selected subbase
kit must be carefully followed. It is the responsibility
of the installer to ensure the connection of
components is done in accordance with these
instructions and all electrical codes.
Branch Circuit and Proper GE
Unit Amperage Rating Subbase Kit
15/20 RAK204D20
30 RAK204D30