SERVICING INSTRUCTIONS
REPLACING PARTS
7.3 Reassemble the interrupter block and leads. Secure the
thermocouple connection in the rear of the gas control (Do
not overtighten). Turn the gas supply on and check the
entire pipework and valve joints for any leaks.
8. MAIN INJECTOR
8.1 Turn the gas supply off at the isolation device. Refer to
Section 2, Replacing Parts to remove the main burner.
8.2 Undo the compression nut from the feed pipe at the gas
control under the appliance.
8.3 Working from inside the firebox, remove the lock nut from
the injector, see diagram 15 and withdraw the injector
complete with the feed pipe from under the appliance. See
diagram 15.
8.4 Holding the injector with a spanner, undo the feed pipe.
NOTE: THE ORIENTATION OF THE INJECTOR.
8.5 Reassemble in reverse order. Turn on the gas supply and
check for any leaks.
9. GAZCO FLUE SURE SYSTEM
9.1 Remove the front door by undoing the four dome nuts and
remove the cast iron door. NOTE: THE CAST IRON DOOR
IS HEAVY. TAKE EXTREME CARE WHEN HANDLING.
Carefully remove the coal retainer and ceramic components
and place to one side. Remove the burner casting by
removing the three screws located on the sides of the burner
skin.
9.2 Remove the screw on the back panel and remove the panel.
Refer to Diagram 17.
9.3 Undo the two screws at the back of the firebox and carefully
withdraw the bracket.
9.4 Disconnect the two slender wires. Undo the two taptite
screws and remove the sensor and the two plastic spacers.
See diagram 19.
AR1607
18
AR1446
19
AR0618
15
AR1605
16
AR1606
17