3.15 Place the top ceramic panel into position so that the two
spring clips slide against the inside of the side panels, gently
position so that it sits centrally in the outer panels. Place the
cast iron grille into the recess in the centre of the top panel,
and locate the blanking plate into the grille, (if required),
see diagram 13.
3.10 Check the pull of the flue system by applying a lighted
smoke pellet to the flue system opening. If there is a
definite flow into the flue, proceed with the installation, if
not warm the flue for a few minutes and repeat the test.
IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY
REQUIRE ATTENTION - SEEK EXPERT ADVICE
3.11 The flue system may now be connected to the stove, ensure
that all joints are sealed with a suitable fire resistant sealant.
It is also recommended that a physical retention method be
used at the flue spigot joint, self-tapping screws being
favoured.
3.12 Connect a suitable pressure gauge to the test point located
on the inlet fitting and turn the gas supply on. Light the
appliance and check all gas joints for gas soundness. Turn
the appliance to maximum and check that the supply
pressure is as stated on the databadge. Turn the gas off and
replace the test point screw, turn the gas on and check the
test point for gas soundness.
4.1 Full instructions are given in Section 2.
4. LIGHTING
INSTALLATION INSTRUCTIONS
INSTALLATION
13