Garmin FA168CPS Home Security System User Manual


 
– 31 –
Security Codes & Authority Levels
Security Codes & Authority Levels Security Codes & Authority Levels
Security Codes & Authority Levels
(Cont.)
(Cont.)(Cont.)
(Cont.)
How to Assign
How to Assign How to Assign
How to Assign Security
Security Security
Security Codes and Attributes
Codes and AttributesCodes and Attributes
Codes and Attributes
The following lists the various command strings for adding security codes and attributes.
Refer to the User Setup chart at the back of this manual for factory
assignments of user attributes and to keep a record of user programming.
NOTE: Partition Master codes (FA168CPS only) apply only to those user numbers
previously assigned (by the system master/installer) to the partition master’s partition.
Add Security Code: System/Partition Master code + [8] + user no. + new user’s security code
(Users 03/33 are preset User 01 = installer User 03 = partition 1 master
to partition programmers, User 02 = master User 33 = partition 2 master
but can be changed.) The Keypad beeps once to confirm that new user was added.
Delete Security Code: System/Partition Master code + [8] + [user no.] + [#] [0]
The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)
Authority Level: System/Partition Master code + [8] + [user no.] + [#] [1]+ auth. level
Factory Assignments: Authority Levels (see definitions on previous page):
users 04-32/34-49 = 0 0 = standard user 3 = duress
users 03/33 = 4 1 = arm only 4 = partition master (FA168CPS only)
2 = guest
Access Group: System/Partition Master Code + [8] + [user no.] + [#] [2]+ group (1-8)
Factory Assignments: none You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
User’s Partition: System Master Code + [8] + [user no.] + [#] [3] + [0] + partition(s) + [#]
(FA168CPS only) This command assigns the partitions the user can access. If more
Factory Assignments: than one, enter partition numbers sequentially, then press [#] to end.
Part. 1 = users 03-32 E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives
Part. 2 = users 33-49 the user access to partitions 1 and 2 and the common partition.
Partition Entries: 1 = partition 1 and common
2 = partition 2 and common
3 = common partition only
RF User Number: Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.
Factory Assignments: none Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see installer).
Zone number: enter the zone number assigned to a button on the
keyfob that will be used for arming/disarming by this user.
Pager On/Off: Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1
Factory Assignments: You can program a user so that a message is sent to a pager
users 01-49 = 1 (on) whenever this code is used to arm or disarm the system.
Paging On/Off: 1 = allow paging; 0 = no paging for this user