Furnace Accessories
A45-1
15/02/13
For G6 & L1 Series Furnaces
Designed for Canadian installations. To convert a natural gas
furnace to LP/Propane gas for altitudes between 0 to 4,500
feet above sea level, the main gas orifice must be replaced.
For higher altitudes (between 2,000 & 4,500 feet above seal
level) the input must be de-rated by 10%. This can be done
by simply reducing the manifold pressure without changing
the gas orifices.
Use on standard & slow opening models only
Not for use with step regulator valves
Application Brand
Part
Number
For use with G6 & L1 series gas furnaces using a
Honeywell Gas Valve
Frigidaire
904091A
For G7 Series Furnaces
Designed for Canadian installations to convert a natural gas
furnace to LP/Propane gas. Used for altitudes between 0 to
4,500 feet above sea level
For altitudes between 0 and 1,999 feet, only the orifice needs
to be changed. For altitudes between 2,000 and 4,500 feet,
both the orifice and the regulator pressure need to be
changed.
Application Brand
Part
Number
For use with G7 series gas furnaces using a
Honeywell Gas Valve
Frigidaire
904915
For G7MQ Modulating Furnaces
Application Brand
Part
Number
For use with G7MQ series gas furnaces Frigidaire
904950
LP Gas Conversion Kits