Frigidaire KG7 Furnace User Manual


 
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377
(403) 244-2161 (403) 381-7707 (306) 933-2433
Furnaces
A45-3
14/12/12
Flue Gas Venting System - System 636™ PVC
Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65
o
C or less
Complete system fully certified to ULC S636
White pipe with unique blue certification markings made to SCH 40 dimensions
NOTES:
1. Do Not
interchange pipe, fittings or chemicals from different BH vent manufactures. Doing so will
void System636™ product certification and warranty.
2. Contractors must check local codes for proper venting
Description Case Part Number
2" Flue Gas Venting System
2" Concentric Vent Termination Kit (no vent screen) 3
196005
2" x 10' Pipe (Straight End) 10
194000
2" Coupling (HubxHub) 70
196352
2" 45
o
Elbow (HubxHub) 110
196242
2" 90
o
Street Elbow (SPxHub) 60
196232
2" 90
o
Long Elbow (HubxHub) 55
196122
2" 90
o
Extra Long Elbow (HubxHub) 40
196022
2" Sanitary Tee (HubxHubxHub) 35
196082
3" Flue Gas Venting System
3" Concentric Vent Termination Kit (no vent screen) 3
196006
3" x 10' Pipe (Straight End) 10
194001
3" Coupling (HubxHub) 60
196353
3" 45
o
Elbow (HubxHub) 25
196243
3" 90
o
Street Elbow (SPxHub) 15
196233
3" 90
o
Long Elbow (HubxHub) 23
196123
3" 90
o
Extra Long Elbow (HubxHub) 15
196023
3" Sanitary Tee (HubxHubxHub) 17
196083
Adapters & Other Components
3" x 2" Increaser Coupling (HubxHub) 45
196364
3" x 2" Reducer Tee (HubxHubxHub) 10
196822
2" x 1 1/2" Reducer Bushing (SPxHub)
Used with #196278
80
196282
1 1/2" x 1/2" Reducer Busing (SPxHose Barb) 80
196278
2" Testing Plug & Bushing Kit (SPxPlug) 10
196143
Cement
PVC Cement, Low VOC (1 pint/473ml) 12
196040
PVC Cement, Low VOC (1 quart/946ml) 12
196041
Transition Cement - To ABS Only (1 pint/473ml) 12
196044
Primer
Primer should be used when installing System636 products at temperatures
below 0
o
C
PVC/CPVC Purple Primer, Low VOC (1 pint/473ml) 12
196042
PVC/CPVC Clear Primer, Low VOC (1 pint/473ml) 12
196017
PVC/CPVC Purple Primer, Low VOC (1qt/946ml) 12
196043
2" Wall Termination Kit (no vent screen) 1
081216
3" Wall Termination Kit (no vent screen) 1
081219
Concentric Vent Kits
These "pipe-in-pipe" kits allow for both exhaust and intake pipes to
penetrate the roof or side wall through only one hole and are
certified with mechanically fastened rain caps
Screw/bolt assembly (included) for mechanically fastening the rain
cap can be easily removed for cleaning or maintenance
Wall Termination Kits
For a traditional vent style, IPEX’s PVC Wall Termination Vent Kits
require only two small wall penetrations for intake and exhaust.
Kits include a white finishing plate with a self sealing foam back
that can be screwed to the exterior wall.
Testing Plug & Bushing Kit
Allows an inline access point for flue monitoring using fully certified
System 636 components. The kit consists of a 2" x 1/2" reducer
bushing (Spig x FPT) and a removable 1/2" MPT plug.
May be installed in new installations or added to existing lines
when monitoring is required
Bushing must be inserted in a 2" fitting socket
May be used on vent lines in any diameter
Certified for use only on IPEX System 636 flue gas vent lines.
Wall
Termination
Kit
Testing Plug
& Bushing
Kit
Concentric Vent Kit