Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377
(403) 244-2161 (403) 381-7707 (306) 933-2433
Furnaces
A45-5
11/06/10
Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces
• 904231 kit fits all G6/L1 series gas furnaces with an "A" width
cabinet. May be configured for air conditioning/heat pump airflows
from 1 1/2 to 3 tons nominal capacity.
• 904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B"
& "C" width cabinets. May be field configured for air conditioning/
heat pump airflows from 2 to 5 tons nominal capacity.
• Designed to maximize system efficiencies, improve air quality and
reduce sound levels
• Air conditioning and heat pump efficiencies up to 16 SEER and 8.5
HSPF
• ECM (electronically commutated motor) variable speed DC motor
allows for 12 selected cooling airflows and 8 heating airflows to
match any applications
• Extra low speed for "fan only" operation
• Extra quiet and smooth blower on and off cycles
• Warranty: Carries the balance of original equipment warranty
Description Part Number
Fits "B" & "C" Width Cabinets for G6: RA,RC,RK,RL series
(not suitable for "B" cabinet 1200 CFM applications)
904075
Fits "A" Width Cabinets for G6 & L1 series
904231
WARNING
Not for use with Model Numbers:
*G6RK096-12B & *GF1RK096-12B
Specifications
904231 904075
Nominal Blower Size
10" x 6" 11" x 10"
Maximum Motor HP
1/2 3/4
Motor Type
Programmable
Variable Speed
Programmable
Variable Speed
Cooling CFM Range*
720 to 1240 720 to 1870
Heating Airflow Range*
550 to 1215 720 to 1800
* Airflow is held constant regardless of external static pressure within the HP and RPM
limits of the motor
Variable Speed Motor Tester - TECMate PRO™
• Designed to assist field service technicians by troubleshooting GE
ECM 2.3 motors independently of the HVAC system
Description Part Number
TECMate Pro™ Variable Speed Motor Tester
904232
Twinning Kit For G7 Single Stage Gas Furnaces
• Provides the capability to combine the operation of two single stage
gas furnaces with PSC motors (not for use with 2 stage, modulating or
variable speed blower models)
• Twinning function not backwards compatible with furnaces manufac-
tured prior to June 2009
Description Part Number
G7 Twinning Kit For Single Stage Gas Furnaces Manufactured After
June 2009
920919