Friedrich RC/RH 80 Air Conditioner User Manual


 
6
www.retroaire.com
The Right Fit For Comfort
EVAP BLOCK OFF
Install
1/2” x 1/2”
Foam Tape
1. Take unit out of packaging.
2. Slide unit into wall sleeve. If supply duct on cooling chassis does
not line up with supply vent on room cabinet it is possible that
factory installed angle brackets on the top and sides will have
to be reversed. This will allow approximately 1” in or out of the
wall sleeve (see figures A & B) below.
3. Slide unit out of wallsleeve.
4. Baffl e Installation - Remove baffl es from kit bag supplied
with unit. Install left and right side baffl es on the condenser
coil in existing holes:
• Choose the proper fi tting baffl es for your application.
• Baffl es must come in contact with the outdoor louver.
5. Apply one piece of 1/2” x 1/2” open cell polyfoam to top fl ange
of evaporator block off (
See illustration at left).
6. Apply 2” x 1 1/2” open cell foam strips around supply air
duct to ensure that all the conditioned air is delivered into
the room. Failure to do so results in recirculation of the
conditioned air around the wall sleeve and through the unit
causing the unit to short cycle and coils to freez, thus rais-
ing operating costs through improper heating and cooling
(Figure C1).
7. 1” x 1” Open cell foam strips are provided to prevent outside air
from entering around the chassis to the room from the sides
and top of the cabinet. Install between wall sleeve and cooling
chassis. It is imperative to have a solid air seal between wall
sleeve and chassis. Failure to do so will result in air leakage
*Refer to the charts on page 23 for electrical and
optional electric heat specifi cations.
RC/RH 10 PERFORMANCE DATA*
Unit Size Cooling Btuh EERs Heat Pump Btuh COP Fresh Air CFM
9 9,500 10.0 8,500 2.8 40/35
12 11,900 10.0 11,400 2.9 40/35
15 14,700 9.2 13,800 2.8 40/35
18 16,900 9.1 N/A N/A 40/35
INSTALLATION INSTRUCTIONS
RC/RH10 REPLACEMENT PTAC
• 1 Installation Manual
• 1 Top Baffl e
• 2 Sets of Lt.&Rt. Baffl es
• Screws
RC/RH10 BAFFLE INSTALLATION KIT
• 1/2” x 1/2” Open Cell Foam Tape
• 1” x 1” Open Cell Foam Tape
• 2” x 1 1/2” Open Cell Foam Tape
• 1ea. 2-Position
Connector & Pin Mate
• 14AWG Yellow Wire
HYDRONIC
ONLY
Two sets of baffl es are provided in your kit to accommodate
mounting brackets in either position A or B.
Make sure baffles are
directed inward toward
the center of coil.
Secure baffl es tightly to
the condenser coil using
the screws provided.
(Figures A1,B1 & C1).
IMPORTANT: The correct
condenser air baffl es must
be installed or performances
may be impaired and/or the
warranty will be voided.
2” X 1 1/2” Supply Air
Duct Foam Tape
CONDENSER SIDE
Baffl es Directed Inward
Toward Coil
Figure C1





from outdoor to
indoor causing
system problems
i.e. coils freezing,
short cycling, and
constant running
of unit. If install-
er is in need of
more foam than
supplied in kit,
consult factory
(Figure D1).
8. Once confi dent that all seals are the correct size and in the
proper location, and the correct baffl es are attached to the con-
denser coil in the proper orientation, slide unit into fi nal position
and tighten any tie down bolts or screws as necessary.
Hydronic Only: Remove the 2-position connector assembly
from kit bag supplied with unit (this will have 2 yellow wires
attached). Connect this 2-position connector to the 2-position
connection located on the bottom of the control box panel.
To
Connect Aquastat:
A.
Remove the black jumper wire located on the bottom
panel of the control box (this is also terminated with a
2-position connector).
B. Cut the jumper wire in the middle and splice the aquastat
to the jumper.
C. Place the connecter back into original location. Refer
to wire diagram on the unit for details.
9. Connect line cord.
10. See Final Inspection and Startup on page 20.
Figure D1
Front View
Cooling Chassis
Wall Sleeve
1x1 Foam Tape
Figure A1
Figure B1