Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS Air Conditioner User Manual


 
6
Screw
Tube
Screw
PXDR10 DRAIN KIT
Architectural Louver Installation (PXAA)
Primary Area:
Condensation from the
chassis collects in the
sleeve in this area. The
Primary Area is the
preferred installation
location.
Installation
1. Screw a threaded metal stud into each of
the holes at the four corners of the louver.
2. From inside the building, grasp the louver at
the vertical supports and maneuver the
louver through the wall sleeve. Pull towards
you until the threaded studs are inserted into
the four holes of the wall sleeve.
3. While holding the louver with one hand, start
washers and nuts on each of the four studs.
Tighten the nuts securely.
CAUTION:
Bodily injury can be caused by louvers falling from a
building during installation. It is recommended that a
safety line be attached to the louver and an anchor
point inside the building during installation.
When using an external drain system, the
condensate is removed through either of two
drain holes on the back of the wall sleeve. Select
the drain hole which best meets your drainage
situation and install the drain kit. Seal off the
other with a cover plate.
Place the drain tube through the gasket and the
mounting plate with the flange toward the wall
sleeve.
Attach the drain tube assembly to one of the
two drain holes at the rear of the wall sleeve.
The large flange on the mounting plate is
positioned at the bottom of the sleeve facing
toward the sleeve. When the drain tube is
positioned at the desired angle, tighten the
screws.
Foam Gasket
Cover Plate
1/2" O.D. Tube
Mounting
Plate
Foam Gasket
Back
of wall
sleeve
Overflow
Slots
Internal Drain Kit Location and Installation (PXDR10)
External Drain
Gasket
1/2" O.D. Tube
Foam Gasket
Mounting Plate
Mounting Plate
Wall Sleeve
Bottom