Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS Air Conditioner User Manual


 
5
Note the use of a lintel under the first course
of bricks above the wall sleeve. Do not use
the wall sleeve as a lintel. The mounting
screw holes shown are to be made by the
installer.
Lintel InstallationLintel Installation
Lintel InstallationLintel Installation
Lintel Installation
Lintel Used To Support
Masonry Walls
Smooth side of clip on Room side
Electrical
Receptacle
16¼"
Electrical Receptacle
42¼"
Minimum
Wall Opening
10" Maximum
Insulation
50"Max
13 ¾"
Main Studs
Jack
Stud
LINTEL
Mounting
Screw Holes
No holes are permitted in the top or bottom of
the sleeve. (Exception: PXDR10 Drain Kit)
Typical Wall Sleeve Installation (PXWS)
IMPORTANT NOTE: The
silicone bead MUST
extend 3" up the side of
the two flanges to
prevent condensate
from leaking.
Wall Sleeve Extension, 42" X 16"
Frame, 20 gauge minimum,
painted or aluminum
Outside Edge
Insulation
Wall Sleeve
Air
Baffles
Four
Condensate
Notches
Condensate Drip
Panel (Field Supplied)
Sealant inside (4) bottom
corners
Width of Wall
Extended Wall Sleeve Installation and Sealant Locations (PXWE)