En-13
SELF-DIAGNOSIS
1
2
Stop the air conditioner operation.
Press the set temperature buttons simultaneously for 5 seconds or more to
start the self-diagnosis.
SU
MO
TU
WE
TH FR
SA
SU
MO
TU
WE
TH FR
SA
Unit number (usually 0)
Error code
ex. Error display ex. Self-diagnosis check
3
Press the set temperature buttons simultaneously for 5 seconds or more to stop the self-diagnosis.
When the error indication “E:EE” is displayed, inspection of the air conditioning system is necessary. Please consult author-
ized service personnel.
How to cleaning
• When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.
• When cleaning the unit’s body, do not use water hotter than 100 °F, harsh abrasive cleansers, or volatile agents like benzene
or thinner.
• Do not expose the unit body to liquid insecticides or hairsprays.
• If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.
CARE AND MAINTENANCE
9368987053_OM_en.p65 12/1/06, 17:0013