Friedrich 2009 Air Conditioner User Manual


 
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
Sleeve P1 does not have thru-the-wall hole dimensions, as these units are fixed chassis and should not be installed thru-the-wall.
NOTE: S,M and L sleeves may be installed in window with no side kits if properly installed.
Sleeve Height Width
Depth
with Front
Shell Depth to
Louvers
Minimum
Extension
Into Room*
Minimum
Extension
Outside*
Window Width
Thru-the-wall Installation
Finished Hole
Minimum** Maximum Height Width Max. Depth
Q 14" 19 ¾" 21
3
8" 8 ½" 5 ½" 10 ¾"
22" 42" 14 ¼" 20" 8 ½”
S 15
15
16" 25
15
16" 27
3
8" 8 ¾" 3
1
16" 16
15
16" 27
3
8" 42" 16
3
16" 26
3
16" 7
3
8"
M 17
15
16" 25
15
16" 27
3
8" 8 ¾" 3
1
16" 16
15
16" 27
3
8" 42" 18
3
16" 26
3
16" 7
3
8
L 20
3
16" 28" 33
5
8" 16 ½" 3
3
16" 18
15
16" 29
7
8" 42" 20
3
8" 28 ¼" 15
1
8"
TWINTEMP
®
models include accessories for thru-the-wall
installation only. Window mounting requires use of optional
accessory kit as listed above.
Window Mounting Kits
TwinTemp Model Kit No.
EQ08L11A WIKQ
ES12L33, ES16L33, YS09L10 and YS13L33. WIKS
EM18L34, YM18L34 and EM24L34. WIKM
EL36L35A and YL24L35. WIKL
Model
Circuit Rating
Breaker or
T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
All XQ MODELS.
KS12L10 and KS15L10. SS08L10, SS10L10,
SS12L10 and SS14L10. EQ08L11A.
YS09L10.
125V - 15A 5 - 15P 6
KM18L30.
SS12L30, SS16L30, SM18L30A and
SM21L30.
250V - 15A 6 - 15P 4
KM24L30. SM24L30 and SL28L30.
ES12L33 and ES16L33. YS13L33.
250V - 20A 6 - 20P 4
SL36L30A. EM18L34, EM24L34 and
EL36L35A. YM18L34 and YL24L35.
250V - 30A 6 - 30P 4
(B)
(A)
(C)
Front
SIDE VIEW
INSTALLATION INFORMATION / SLEEVE DIMENSIONS
Circuit Rating / Breaker
8