FMI (V)G42H/50H Indoor Fireplace User Manual


 
www.fmiproducts.com
109493-01R 7
Figure 6 - Lineal Gain

  
Georgian Fireplace 66
1
/
2
"
12-12DM
12-12HT
Pipe Section 10
5
/
8
"
18-12DM
18-12HT
Pipe Section 16
5
/
8
"
24-12DM
24-12HT
Pipe Section 23
5
/
8
"
36-12DM
36-12HT
Pipe Section 34
5
/
8
"
48-12DM
48-12HT
Pipe Section 46
5
/
8
"
RLT-12D
RLT-12HT
Round Termination 7
3
/
4
"
*
STL-12D
Square Chase-Top
with Slip Section
7
"
to 15
"
*
* The lineal gain for the terminations is mea-
sured to the ue gas outlet height.
Hemmed
End
12
3
/
8
"
Stainless
Inner Pipe
15" Galvanized
Outer Pipe


Each double wall chimney section consists of a
galvanized outer pipe, a stainless steel inner ue
pipe and a wire spacer. Pipe sections must be
assembled independently as chimney is installed.
When connecting chimney directly to replace,
the inner ue pipe section must be installed rst
with lanced side up. The outer pipe section can
then be installed over the ue pipe section with
hemmed end up. Press down on each pipe sec-
tion until lances securely engage hem on replace
starter. The wire will assure the proper spacing
between inner and outer pipe sections.
Continue to assemble chimney sections as
outlined above, making sure that both inner and
outer pipe sections are locked together. When
installing double wall snap-lock chimney to-
gether, it is important to assure the joint between
chimney sections is locked. Check by pulling
chimney upward after locking. The chimney
will not come apart if properly locked. It is not
necessary to add screws to keep the chimney
together (exception, see Figure 9, page 9).
VENTING INSTALLATION
Figure 5 - Outside Air Kit
Secure to Collars with Metal Tape,
Screws or Straps (Min. 1/4" x 20" size)
Air Inlet
Location
Must Allow
For Bushes
or Snow
Vent Hood
Required for
Wall Installation
Air Inlet
Eyebrow
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

The FMI PRODUCTS, LLC chimney system
consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned
for maximum adaptability to individual site
requirements. Actual lengths gained after
tting overlaps must be taken into consider-
ation (lineal gain) and are given in the lineal
gain chart (see Figure 6). Lineal Gain is the
actual measurable length of a part after two
or more parts are connected. For Canada,
use chimney parts designated "HT".

the collar around the chimney at

be obstructed. Never use blown
    
enclosure.


The installation of an outside air kit should
be performed during the rough framing of
the replace due to the nature of it's location.
Outside combustion air is accessed through
a vented crawl space (AK4F) or through a
sidewall (AK4).
  
inlet ducts shall not terminate
in attic space.