125078-01B 23
5. Turn equipment shutoff valve clockwise
to the OFF position (see Figure
33). Do not force.
6. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information page 22. If you
don't smell gas, go to the next step.
7. Turn equipment shutoff valve counter-
clockwise to the ON position. Do
not force.
8. Replace center brick/control cover.
9. Turn on all electric power to appliance.
10. Turn safety shutoff switch to the ON
position.
11. Visually locate pilot. Ignitor should begin
to spark and main burner should ignite
once ame appears at pilot.
• If lighting appliance for the rst time each
season, it may take several attempts
before supply gas can reach pilot and
main burners.
• If appliance will not stay lit after several
attempts, follow instructions under To
Turn Off Gas To Appliance and call your
service technician or gas supplier.
Sensing Rod
Pilot
Burner
Ignitor
Figure 34 - Pilot
OPERATION
Continued
TO TURN OFF GAS
TO AppLIANCE
1. Turn off safety shutoff switch.
2. Turn off all electric power to appliance if
service is to be performed.
3. Remove center brick/control cover.
4. Turn equipment shutoff valve clockwise
to OFF. Do not force.
5. Replace center brick/control cover.
REMOTE
OpERATION
1. Turn equipment shutoff valve to ON posi-
tion. You can now turn the burner on and
off with hand-held remote control unit.
IMPORTANT: Be sure to press ON/OFF
buttons on hand-held remote control unit
for up to 3 seconds to assure proper
operation.
2. Press ON/OFF button to turn burner on
and off.
IN
PILOT
IN
OUT
VENT
TH
TP
TH
TP
Figure 33 - Turning Equipment Shutoff Valve to the OFF Position
Equipment
Shutoff Valve