FMI (V)DVF42NS Indoor Fireplace User Manual


 
www.fmiproducts.com
125078-01B 19
FIREPLACE INSTALLATION
Continued
3. Make sure control knob of replace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 22 or
Figure 23, page 18). Apply noncorrosive
leak detection uid to all joints. Bubbles
forming show a leak. Correct all leaks at
once.
5. Light replace (see Operation, page 22).
Check all other internal joints for leaks.
6. Turn off replace (see To Turn Off Gas to
Appliance, page 23).
REMOVING/REPLACING GLASS
DOOR
CAUTION: Do not operate
this replace with a broken glass
door panel or without the glass
door panel securely in place.
For replacement part informa-
tion see Replacement Parts,
page 36.
CAUTION: Wear gloves and
safety glasses while handling
or removing broken glass.
Do not remove if glass is hot.
Keep children and pets away
from glass.
WARNING: If replace has
been running, turn off replace.
Let cool before removing glass
doors.
Figure 24 - Removing/Replacing Door
Removing Glass Door
If replacement of glass is necessary, the entire
frame assembly must be replaced. Gloves
must be worn when removing/replacing glass
door. If glass is broken tape remaining glass
onto frame before removing.
1. Remove screens if installed.
2. Open bottom access panel.
3. Unlock 2 door latches on bottom of
rebox.
4. Tilt open glass door 45° from the bottom
of rebox and lift up to release door from
rebox top retainer (see Figure 24).
Replacing Glass Door
1. Position door frame in front of rebox
opening with bottom of door tilted away
from rebox (see Figure 24).
2. Hook top ange of door frame over top of
rebox frame.
3. Secure 2 bottom door latches.
Door
Retainer
Glass
Door
Bottom
Access Panel
Door
Latches