AIR FOR COMBUSTION AND VENTILATION
Continued
Figure 3 - Ventilation Air from Inside
Building
Or
Remove
Door into
Adjoining
Room,
Option
2
V entilation
Grills
Into Adjoining
Room,
Option 1
4"
Figure 4 - Ventilation Air from Outdoors
Outlet
Air
V entilated
Attic
Outlet
Air
Inlet
Air
Inlet Air
V entilated
Crawl Space
To
Crawl
Space
To Attic
INSTALLATION
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining
unconned space. When ventilating to an
adjoining unconned space, you must provide
two permanent openings: one within 12" of the
ceiling and one within 12" of the oor on the
wall connecting the two spaces (see option
1, Figure 3). You can also remove door into
adjoining room (see option 2, Figure 3). Fol-
low the National Fuel Gas Code ANS Z223.1/
NFPA 54 Air for Combustion and Ventilation
for required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
and one within 12" of the oor. Connect these
items directly to the outdoors or spaces open
to the outdoors. These spaces include at-
tics and crawl spaces. Follow the National
Fuel Gas Code ANS Z223.1/NFPA 54 Air for
Combustion and Ventilation for required size
of ventilation grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.
NOTICE: This rebox in com-
bination with unvented log
sets are intended for use as
supplemental heat. Use along
with your primary heating
system. Do not install them as
your primary heat source. If you
have a central heating system,
you may run system’s circulat-
ing blower while using heater.
This will help circulate the heat
throughout the house. In the
event of a power outage, you
can use unvented logs as your
primary heat source.
WARNING: A qualied ser-
vice person must install rebox.
Follow all local codes.
WARNING: Never install the
rebox
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other ammable
objects are less than 42" from
the front, top or sides of the
rebox
• in high trafc areas
• in windy or drafty areas