TROUBLESHOOTING
Continued

When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition
ODS/pilot lights but flame
goes out when control knob
is released
Burner does not light after
ODS/pilot is lit

1. Gas supply turned off or
equipment shutoff valve
closed
2. Control knob not in PILOT
position
3. Control knob not pressed
in while in PILOT position
4. Air in gas lines when
installed
5. Depleted gas supply (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
1. Control knob not fully
pressed in
2. Control knob not pressed
in long enough
3. Safety interlock system
has been triggered
4. Equipment shutoff valve
not fully open
5. Pilot flame not touching
thermocouple, which al-
lows thermocouple to cool,
causing pilot ame to go
out. This problem could
be caused by one or both
of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple connection
loose at control valve
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too
low
2. Burner orice is clogged
3. Thermopile leads discon-
nected or improperly con-
nected (Remote-Ready
Models Only)
4. Burners will not come on in
remote position (Remote-
Ready Models Only)
REMEDY
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while
in PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP
gas company
6. Clean ODS/pilot (see Clean-
ing and Maintenance, page
24) or replace ODS/pilot
assembly
7. Replace gas regulator
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Wait one minute for safety
interlock system to reset.
Repeat ignition operation
4. Fully open equipment shut-
off valve
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 24) or replace ODS/
pilot assembly
6. Hand tighten until snug,
then tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or
propane/LP gas company
2. Clean burner (see Cleaning
and Maintenance, page 24)
or replace burner orice
3. Reconnect leads (see Wir-
ing Diagram, page 29)
4. Replace battery in hand-
held remote and receiver