FMI CGMFN Indoor Fireplace User Manual


 
www.fmiproducts.com
119315-01D14
INSTALLATION
Continued
We recommend that you install a sediment
trap in supply line as shown in Figure 14. Lo-
cate sediment trap where it is within reach for
cleaning. Install in piping system between fuel
supply and heater. Locate sediment trap where
trapped matter is not likely to freeze. A sediment
trap traps moisture and contaminants. This
keeps them from going into replace controls.
If sediment trap is not installed or is installed
wrong, replace may not run properly.
* Purchase the optional equipment shutoff
valve from your dealer. See Accessories,
page 34.
Figure 14 - Gas Connection
Equipment Shutoff
Valve With 1/8" NPT
Tap*
3" Minimum
Approved
Flexible Gas
Line
Pipe Nipple Cap Tee Joint

From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)
NATURAL
From Gas Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Sediment Trap


Installation Items Needed
Phillips screwdriver
sealant (resistant to propane/LP gas, not
provided)
  
    
   
-

   



Figure 15 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
Flexible Gas Line
from Fireplace Gas
Regulator Provided
With Fireplace
To Gas Regulator
(Manual-Controlled
Models) or Control
Valve (Remote-
Ready Models)
Equipment
Shutoff Valve

To External
Regulator
NATURAL
To Gas Supply
1. Route exible gas line, included, from
fireplace control to equipment shutoff
valve through side or rear access holes
in outer casing (see Figure 1, page 5).
2. Apply pipe joint sealant lightly to male
threads of gas connector attached to
exible gas line/equipment shutoff valve
(see Figure 15).



   


    
   
   

3. Check all gas connections for leaks. See
Checking Gas Connections.
4. Feed exible gas line into replace base
area while replacing branch support. Make
sure the entire exible gas line is in replace
base area.