FMI CGMFN Indoor Fireplace User Manual


 
www.fmiproducts.com
119315-01D16
INSTALLATION
Continued

CONNECTIONS
1. Open equipment shutoff valve (see Figure
16, page 15).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of replace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas regulator (Manual-Controlled
Models) or to gas control valve (Remote-
Ready Models) (see Figures 17 or 18,
page 15). Apply noncorrosive leak de-
tection uid to all joints. Bubbles forming
show a leak.
5. Correct all leaks at once.
6. Light replace (see Operating Fireplace,
page 18). Check all other internal joints
for leaks.
7. Turn off replace (see To Turn Off Gas to
Appliance, page 20 for Manual-Controlled
Models or page 21 for Remote-Ready
Models).